7
Alarm override switch
Self-contained smoke detector/alarm Cat. No. 0 405 17 has an alarm
override function:
• when the source of the smoke has been identified
• as a preventive measure before smoke is likely to occur
Example: smoke from a toaster, deep fat fryer, cigarette. The override is
automatically disabled after 10 min.
The self-contained smoke detector/alarm then reverts to its normal
operating mode. This allows you to ventilate the room without setting off
the alarm audible signal.
Overriding the alarm with
smoke present
Overriding the alarm before smoke is
present
1 - Smoke present:
- 1 red flash/1 sec
- alarm audible signal
1 - Before smoke is present:
- Smoke alarm in standby state
- 1 red flash/50 secs
2 - Press the Test button, the
alarm signal stops.
2 - Now hold down the Test button for
2 seconds. After the test audible
signal, 3 short beeps confirm override
mode.
3 - The override is active for 10 minutes:
- 1 red flash/7 secs (if smoke present: 1 red flash/2 secs)
The smoke alarm is overridden for 10 min.
Resetting a self-contained smoke detector/alarm which is in override mode
Override mode can be cancelled before the 10 minutes are up.
1 - Smoke alarm in
override mode:
1 red flash/7 secs
if smoke present.
2 - Press the Test button,
2 short beeps cancel
override mode.
3 - Returning the
self-contained smoke
detector/alarm to
standby state:
1 red flash approx.
every 50 secs.