Fire fronts are now available in many different designs and finishes. The user can now choose their own
particular style of fire front to suit their individual fireplace setting, providing the fire front complies with the
following dimensions -
Fire Front -
(X) Max: 210mm
Min: 190mm
Ash Pan Cover -
(W) Max: 90mm
Min: 65mm
(Y) Max: 345mm
Min: 320mm
SAFETY WARNING - This appliance has a naked flame and as with all heating appliances a fireguard
should be used for the protection of children, the elderly and infirm. Fireguards should conform to
BS 6539 (1984 Fireguards for use with solid fuel appliances). This fire is not fitted with an integral
guard. In normal use consideration may be given to the use of a fireguard confirming to BS 6539,
such that the approach to the naked flame is minimised.
CLEANING AND MAINTENANCE
CONTINUED
11
w
Y
X
Minimum area free space 15cm
2
Minimum area free space 5cm
2
Fig. 12
Slide Control Lever
- The slide control mechanism should be greased annually with high temperature grease.
Place a small amount of grease at the top and bottom of the lever guide and operate the lever several times to
work the grease into the guide.
Battery Replacement
- The battery will need replacing from time to time. To change the battery, switch off the
appliance and leave to cool down. Remove the fire front and locate the battery holder (Fig.11a). This is located
at the bottom left hand side of the appliance. Remove the battery. Replace with a good quality alkaline battery.
Fig. 11a
Ignition System Wiring Diagram
9 volt battery
Ignition Assembly
FIRE FRONT SPECIFICATIONS