Legato NetWorker, Release 7.0
Disaster Recovery Guide
Chapter 6: Microsoft Cluster Disaster Recovery (Windows NT 4.0)
6
125
4. Install the latest service pack software on Node_B. Make sure the version
is greater than Service Pack 3.
5. If NetWorker Server is installed in Node_A as a failover server:
a. Install NetWorker server software.
b. Register the resource extension. This manages the NetWorker server
resource type in Node_B. For more details, refer to the Legato
NetWorker Installation Guide, Microsoft Windows Version.
c. On Node_B, you can choose to:
– Configure the tape devices
– Install the NetWorker client software
6. Install any NetWorker specific patches.
7. Recover all the data that belongs to Node_B. This includes the system
configuration data. For example:
•
System State
•
RepairDisk
•
Windows NT 4.0 %SystemRoot% directory
•
C:
8. Reboot Node_B.
9. Verify that the system has been restored to its original state before the
disaster.