LI3000 

Uninterruptible Power Supplies

 

 

 

15 

 

 

Contact your dealer or call the number in this manual for information on battery replacement.     
 

Read and follow the IMPORTANT SAFETY INSTRUCTIONS before servicing the battery. 

Servicing the battery can only be performed by trained personnel

 

knowledgeable of 

batteries and their precautions.

 Keep unauthorized personnel away from batteries.

 

 

CAUTION! 

Use only the specified type of battery. See your dealer for replacement batteries. 

CAUTION! 

The battery may present the risk of electrical shock. Do not dispose of batteries in 

a fire, as they may explode. Follow all local ordinances regarding proper disposal of batteries. 

CAUTION! 

Do not open or mutilate the batteries. Release electrolyte is harmful to the skin 

and eyes and may be toxic. 

CAUTION!

 

A battery can present a high risk of short circuit current and electrical shock.   

Take the following precautions before replacing the battery: 

1. Remove all watches, rings or other metal objects. 

2. Only use tools with insulated handles. 

3. Do not lay tools or metal parts on top of battery or any terminals. 

4. Wear rubber gloves and boots. 

5. Determine if the battery is inadvertently grounded.    If inadvertently grounded, remove 

source of ground. 

CONTACT WITH GROUNDED BATTERY CAN RESULT IN 

ELECTRICAL SHOCK! 

The likelihood of such shock will be reduced if such grounds are 

removed during installation and maintenance (applicable to a UPS and a remote battery 

supply not having a grounded circuit).   

 
REMINDER

: Batteries are considered as 

HAZARDOUS WASTE

 and must be disposed of 

properly. Contact your local government for more information about proper disposal and 
recycling of batteries. 

 

STORAGE: 

First turn off your UPS and disconnect its power cord from the wall outlet. Disconnect all 
cables connected to the UPS to avoid battery drain. To store your UPS for an extended period, 
cover it and store with the battery fully charged. Recharge the battery every three months to 
insure battery life. If the battery remains uncharged for an extended period of time, it may 
suffer permanent loss of capacity.

 

 
 

BATTERY REPLACEMENT 

Summary of Contents for Lineage LI3000

Page 1: ...User s Manual Lineage LI3000 UPS K01 1120005 00...

Page 2: ...E POWER REQUIREMENTS OF YOUR EQUIPMENT 4 TO ESTIMATE POWER REQUIREMENTS 5 HARDWARE INSTALLATION 5 BASIC OPERTAION 8 FRONT PANEL DESCRIPTION 8 REAR PANEL DESCRIPTION 9 TROUBLESHOOTING 12 TECHNICAL SPEC...

Page 3: ...remove the risk Voltage may still be present from the battery pack The battery pack quick connectors should be disconnected before performing maintenance or service work on the UPS When replacing the...

Page 4: ...ower supplied outlets does not exceed the UPS unit s rated capacity 3000VA 2200W for LI3000 If rated unit capacities are exceeded an overload condition may occur and cause the UPS unit to shut down or...

Page 5: ...eceipt However recharging the battery for at least four hours is recommended to insure that the batteries are fully charged Charge loss may occur during shipping and storage To recharge the battery si...

Page 6: ...indicator light will illuminate 7 Your UPS is equipped with an auto charge feature When the UPS is plugged into an AC outlet the battery will automatically recharge 8 To maintain optimal battery char...

Page 7: ...LI3000 Uninterruptible Power Supplies 7 Figure 1 Connecting LI3000 with Battery Pack...

Page 8: ...it returns to on line operation If the UPS fails the self test please recharge the battery for 4 hours and perform another self test If it fails after recharging the battery please replace the batter...

Page 9: ...the UPS outlets are providing clean power free of surges and spikes Battery Indicator This illuminates during utility failure indicating that the battery is supplying power to the battery power suppl...

Page 10: ...insures uninterrupted operation of connected equipment during a power failure NOTE When the UPS is overloaded the other six minor outlets will not provide power to equipments prior to the Individual B...

Page 11: ...shutdown User Control delay can be set in the SeeUPS2020 Plus software Recommended time is 5 minutes Once the Primary computer is shutdown the UPS will signal the Secondary computer and initiate the...

Page 12: ...seconds and then turn the UPS on The unit is not connected to an AC outlet The unit must be connected to a110 120V 50 60Hz outlet The battery is worn out Contact Legacy Power Conversion about replace...

Page 13: ...y Yes Physical Total of UPS Receptacles 7 Maximum Dimensions 2U Rack 2 Weight lbs 122 5 Battery Sealed Maintenance Free Lead Acid Battery 7AHx8 Typical Recharge Time 8 Hours Warning Diagnostics Indica...

Page 14: ...s providing battery power to the Battery backup outlets Off Off On Set Rapid Beeps Utility Failure The UPS is providing battery power Rapid beeps indicate the battery will run out of charge within a f...

Page 15: ...rings or other metal objects 2 Only use tools with insulated handles 3 Do not lay tools or metal parts on top of battery or any terminals 4 Wear rubber gloves and boots 5 Determine if the battery is i...

Page 16: ...f the Product and therefore entitled coverage under the Limited Warranty Registration is not required for Limited Warranty coverage but note if you do not complete a registration card you will be requ...

Page 17: ...Product if defective within a reasonable time Legacy will refund to you the full purchase price you paid for the Product purchase receipt showing price paid is required CONDITIONS TO THE LIMITED WARR...

Page 18: ...e States or Provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitation may not apply to you DO NOT USE FOR HIGH RISK ACTIVITIES Legacy does not s...

Page 19: ...ase the separation between the equipment and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced...

Reviews: