SPA TROUBLE SHOOTING GUIDE
Note: For wiring outside of U.S. and Canada, GFCI may be referred to as a RCD (residual current
device). Be sure all local electrical codes are followed.
NOTHING ON THE SPA OPERATES
1.
Check the control panel display for any messages. If there is a message, refer to the diagnostic
section on that model spa. There you will find the meaning of the message and what action is
to be taken.
2.
If there is no message on the control panel and the control panel is completely dark (off), try to
reset the GFCI breaker.
The GFCI should be located in a weather proof box close to the spa,
but no closer than 5 ft.
If the spa does not respond, or the GFCI breaker continues to trip, contact your local Master Spas
dealer or service company.
PUMP(S) DO NOT OPERATE -
1.
Press the “Jets” button on your control panel.
If you hear the pumps trying to operate:
A. Check that all the slice valves are open.
B. Pump may need to be primed.
C. Check that the air controls are open.
Refer to Installation Instructions section.
If you do not hear anything from the pump, contact
your local service company.
POOR JET PERFORMANCE
1.
Make sure pump is operating.
2.
Check that the water level is adequate (up to minimum safe water level on sticker located near
filter.)
3.
Make sure the jets are open and the air controls are open.
Refer to Glossary of Spa Technology
section.
Summary of Contents for LW 524
Page 1: ...A H E R I T A G E O F Q U A L I T Y OWNER S MANUAL ...
Page 2: ......
Page 39: ...37 DO NOT DIVE SITE PREPARATION GENERAL GUIDELINES 102 DO NOT DIVE ...
Page 60: ...58 DO NOT DIVE Spa Controls Pump Diagrams LW 524 Pump 1 Air Control Pump 1 REV 012018 ...
Page 61: ...59 DO NOT DIVE Spa Controls Pump Diagrams LW 715 Pump 1 REV 012018 Pump 1 Air Control ...
Page 75: ......