Page 1: ...IMPORTANT SAFETY INSTRUCTIONS L200 L200C SERIES OWNER S MANUAL I VITA INTERNATIONAL 2320 N W 147th Street Miami Florida 33054...

Page 2: ...ntenance We suggest that you take some time to carefully review it Please keep this manual available for reference If you have any questions regarding your VIta Spa set up operations or maintenance pl...

Page 3: ...TELEPHON E SERIAL MODEL To contactour TechnicalServiceDepartment pleasewrite to Vita International 2320 NW 147th Street Miami FL33054 or call 1 305 685 2063 during normal business hours Mondaythrough...

Page 4: ...et 15 D PanelLock 15 E FreezeProtection 16 17 F FlowProtection 16 G OverheatProtection 16 H Diagnostics 16 Add StartUp Chemicals 16 JetOperation 17 A Three Way Power Diverter Valve 17 B Turbo Massage...

Page 5: ...on fittings or the pump be sure that the flow rates are compatible Never operate the spa if the suction fittings are broken or missing Never replace a suction fitting with one rated less than the flow...

Page 6: ...d FaultCircuitInterrupter CFCI protectedcircuit ThisGFCIisrequiredbythe NationalElectrical Code NEe and must be installedby licensedelectrician Testthe GFCImonthly Testthe water withyour hand before e...

Page 7: ...pa 5 fetal damage in pregnant women and 6 unconsciousness resulting in a danger of drowning WARNING The use of alcohol drugs or medication can greatly increase the risk of fatal hyperthermia in spas P...

Page 8: ...etc may pose obstructions to deliver the spa to its intended site Trees lawn placement surfaces etc can create extra work in keeping your spa area dean and safe Please be advised that placing your spa...

Page 9: ...EBRANCHES Clearancefor spapassage 3 TIGHTCORNERS Makesure there is spaceto maneuver 4 STORAGE SHEDS DOG HOUSES WOODPilES Removeout of the way 5 GATES CLEARANCE FORPASSAGE OFSPA Doesgateneedto be remov...

Page 10: ...LDBE 6 BARE COPPER ALL SPASREQUIRE THE USE OF AN ISOLATEDGFCI PROTEGEDCIRCUIT THE INSTALLATION OF A DISCONNEG IS REQUIRED NO MORE THANTEN 10 VISUAL FEET FROMTHESPAAND NOTLESS THAN FIVE 5 FEET THISREQU...

Page 11: ...1 GrCI DISCClNNECT SEPARATE NEUTRAL WEAK GROUND OR ROMEXWIRE USEDTO FEEDGFCIWITH UNDERSIZED GROUNDWIRE AIN PAN L N c G GrCJ DISCDNN CT c ill l OIHZ Gr ouod Sf A T IIH COMMON NEUTRAL GROUNDBAR IN MAIN...

Page 12: ...Z GrO lOd L i J LrrR lN CiFCIIN PANELWITH COMMON NEUTRALBARAND OR ROMEX WITH UNDERSIZED WIRE USEDTO FEEDDISCONNECT HAIN PANEL N Co DISC JNN CT 11 0 L2 QGrO lOd SPA TE NINIII GFCIIN PANEL WITHSEPARATE...

Page 13: ...0 LI L2 u SPA T GFCIMOUNTED IN PANEL AND DISCONNEcr MOUNTED INSIDETO COMMONWALLWITHMETAL STUDS ORWITHMETAL MOUNTINGBOX MAIN PANEL If j DISCONNECT LI LZ 0 c 0 M d SPA T RM GFCIIN PANEL WITHWEAKGROUND O...

Page 14: ...iances or lights sharing power on this circuit 3 Refer to the wiring diagram posted inside the electrical equipment door to determine the current voltage and wire size requirements for your spa 4 THHN...

Page 15: ...ews provided attach the locks and insert the cover tie down straps Utilizing the cover anytime the spa is not in use will reduce heat loss and thereby reduce the amount of running time required to mak...

Page 16: ...SETI1NGTEMPERAlURE 1 Press PROC to display water temperature 2 Press UP or DOWN arrows to choose the desired temperature Notice the heater icon flashing 3 Wait 30 seconds or press any function button...

Page 17: ...ROG one more time to showthe Hour ObseNethe flashingclock icon and PM indicator No indicator means AM 3 Press UP or DOWN to select the current hour 4 Press PROG one more time to show the minutes 5 Pre...

Page 18: ...ms All settings existing at the time of the power failure will be restored when power retums C SYSTEM RESET Anytime there is reason to believe that your spa electronic system is not operating properly...

Page 19: ...n effort to control the amperage draw and conserve electricity the heater will run if the primary pump is taJmed onto low speed but then shut off whiile the primary pump goes to high speed or if the s...

Page 20: ...alve to the left water will be diverted to MAn jet s giving that zone the maximum output Rotating the valve to the right will give M8 jet s the maximum output When turned to the center both Anand M8nw...

Page 21: ...e water pressure can be adjusted in both jets by rotating the outer rim of the jet clockwise for minimum pressure and counter clockwise for maximum pressure Water pressure can also be varied by openin...

Page 22: ...used to introduce air into the water jet stream They allow the user to increase open jet pressure or decrease close jet pressure as desired G CLUSTER JETS These jets work as a team that s why they re...

Page 23: ...ed with an aroma dispenser located on the lip of the spa To activate VitAroma insert one of Vita Spa s exclusive aromatherapy scents and turn on the VitAroma Induction System You will immediately expe...

Page 24: ...s way one can be soaking and cleaning while you continue to enjoy the use of your spa DRAINING YOUR SPA Detergent residues f ombathing suits as well as soap film from your body may graduallyaccumulate...

Page 25: ...water Condition the vinyl after cleaning by applying a thin film of vinylconditioner NOTE Toremovetree saps use lighterfluid not charcoal lighter but the kind used in cigarette lighters Use sparingly...

Page 26: ...DIVERTER VALVE Over a period of time sand or grit may intrude into your spa The diverter valves may become difficult to tum It is important that the debris be removed as soon as possible to avoid dama...

Page 27: ...rganiccompounds in the spa water a sanitizer must be used regularly The use of ozone as an oxidizer has proven to be an effective method to help maintain water cleanliness but a residual chemical sani...

Page 28: ...t calcium build up Calciumhardness 120to 250 ppm Sprayfilter element to remove loose particles MONTHLY Four to six weeks Two to three months Inspect and clean the spa filter cartridge It is important...

Page 29: ...odiumdichloris the recommended type of sanitizer Sodium dichlor dissolves easily and has a neutralpH which minimizes the effect that the addition of a sanitizerhas on a pH balance Trichlor compounds a...

Page 30: ...nge 80 to 120 ppm it should be adjusted first If it is low raise the alkalinity by adding PH UP 1 oz at a time retesting until the alkalinity reaches 120 ppm If the alkalinity is high it should be low...

Page 31: ...d FRIDAY 1 Nothingrequired if Bromineis used as sanitizer Check and adjust ChlorinelevelifChlorine is used Note The above table is an example only Actual spa usage will determine the amount of chemica...

Page 32: ...which has a very low pH 2 6 dissolvesvery slowly is highly concentrated and was designed for concrete or plaster swimming pools It will cause damage to your spa CHEMICALSAFETYINSTRUCTIONS when using...

Page 33: ...efill Excessive Organics Shockthe spawith POTASSIUM Too manychlolamines bromamines PEROXY MONOSULFATE insuffident free availal 4echloline Improper sanitation Low pH Increase sanitizer level recommende...

Page 34: ...efill Excessive Organics Shockthe spawith POTASSIUM Too many chbramines bromamines PEROXY MONOSU LFATE insufficient free available chlorine Improper sanitation Low pH Increase sanitizer level recommen...

Page 35: ...just water Clean filter with a filter cleaner or degreaser Shock with POTASSIUMPEROXY MONOSULFATE adjust pH Shock with POTASSIUM PEROXY MONOSULFATE maintain sanitizer at recommended level Raise pH wit...

Page 36: ...r HP Highvoltage LP LowVoltage Pl Pump1 Error P2 Pump2 Error Pb Power Board Communication PS PressureSwitch Error LS WaterSensor 5S HeaterSensor HILI HighLimitSensor Deteds Temperature Rise Abo 112F O...

Page 37: ...ater is on Flashing Temperature Adjustment Mode e Still Economy Mode No timer Icon means Standard Mode Flashing Day and Time Adjustment Mode Flashing Panel lock All buttons are deactivated t Still Fil...

Page 38: ...Maintenance Log Use this page to keep a record of when you performany maintenance on your spa PAGE 34...

Page 39: ...Maintenance Log...

Page 40: ...sonable costs to pick up the defective spa and retum it or delivering and instailing the replacement spa will be the responsibility of the spa owner EXCLUSIONS This warranty is void Vrta International...

Page 41: ...Registered Trademark of Vita International Division of JTI MIAMI FLORIDA OM Ir dustties Ltc 23 3 Nf rth est 14 Sueet Miam Rorida 33054 Phone 305 685 2063 or 305 908 8187 Toll Free 877 240 9457 FAX 305...