To prevent premature failure of your spa cover and the possibility of water running out of
the spa off the bottom of the cover, always turn Laminar Flow Jets down so that they do not hit
the cover when the cover is closed. You do not want to completely turn jets off. Doing so may
cause a build up of stagnant water in the water line if not used often.
CARE OF YOUR OZONE SYSTEM
The ozone hose and check valve connecting between the ozone generator and ozone injector
should be inspected and/or replaced, if necessary, every 12 months. Depending on conditions
of the air which is being brought in to the ozone generator, the ozone hose and check valve
can wear more rapidly. This regular maintenance is not covered under the spa warranty. We
recommend that your Master Spas Dealer or Service Center be contacted to perform this type of
maintenance.
CARE OF LAMINAR FLOW JETS:
In order to keep your Laminar Flow Jets operating properly, follow these instructions in sequence:
- Turn off Laminar Flow Jets
- Remove outer ring by turning face counter clockwise
- Remove internal Jet insert with a pair of needle nose pliers
- Clean plastic filter at the back of the Jet insert so all holes are free of debris
- Reinstall Jet insert and outer ring
NOTE: These maintenance procedures are the responsibility of the spa owner to perform. These
procedures are not covered by the spa warranty.
CLEANING JETS
The majority of jets in your spa can individually be turned on/off. If any of
these jets become hard to turn, it will be necessary to remove the jet to
clean it as grit/sand and mineral deposit may be present.
The jets in your spa can be removed for cleaning by unscrewing them
(counter clockwise) and then pulling out the jet.
TO CLEAN JETS:
Place the jet(s) in a container, fully immerse in white vinegar. Let the jet(s) soak
overnight and then rinse with water. Reinstall the jet(s). It may be necessary to clean grit and
deposits from the white jet body (mounted in the spa shell) by using a small bristled brush.
Summary of Contents for LW 524
Page 1: ...A H E R I T A G E O F Q U A L I T Y OWNER S MANUAL ...
Page 2: ......
Page 39: ...37 DO NOT DIVE SITE PREPARATION GENERAL GUIDELINES 102 DO NOT DIVE ...
Page 60: ...58 DO NOT DIVE Spa Controls Pump Diagrams LW 524 Pump 1 Air Control Pump 1 REV 012018 ...
Page 61: ...59 DO NOT DIVE Spa Controls Pump Diagrams LW 715 Pump 1 REV 012018 Pump 1 Air Control ...
Page 75: ......