46
DO NOT DIVE.
102
DO NOT DIVE.
Spa Controls - 120V Models
Spa Diagnostic Messages
MESSAGE
MEANING
ACTION REQUIRED
No message on display.
Power has been cut off to
the spa.
The control panel will be disabled until power
returns. Spa settings will be preserved until
next power up.
Temperature unknown.
After the pump has been running for 2 min-
utes, the temperature will be displayed.
“Overheat” - The spa
has shut down. One of the
sensors has detected 118°F
(48°C) at the heater.
DO NOT ENTER THE WATER. Remove the spa
cover and allow water to cool. Once the heater
has cooled, reset by pushing any button. If spa
does not reset, shut off the power to the spa
and call your dealer or service organization.
“Overheat” - The spa has
shut down. One of the sen-
sors has detected that the
spa water is 110°F (43°C).
DO NOT ENTER THE WATER. Remove the
spa cover and allow water to cool. At 107°F
(42°C), the spa should automatically reset. If
spa does not reset, shut off the power to the
spa and call your dealer or service organiza-
tion.
“Ice” - Potential freeze con-
dition detected.
No action required. The pump(s) will automati-
cally activate regardless of spa status.
Spa is shut down. The sen-
sor that is plugged into
the Sensor “A” jack is not
working.
If the problem persists, contact your dealer or
service organization. (May appear temporarily
in an overheat situation and disappear when
the heater cools.)
Spa is shut down. The sen-
sor that is plugged into
the Sensor “B” jack is not
working.
If the problem persists, contact your dealer or
service organization. (May appear temporarily
in an overheat situation and disappear when
the heater cools.)
Summary of Contents for LW 524
Page 1: ...A H E R I T A G E O F Q U A L I T Y OWNER S MANUAL ...
Page 2: ......
Page 39: ...37 DO NOT DIVE SITE PREPARATION GENERAL GUIDELINES 102 DO NOT DIVE ...
Page 60: ...58 DO NOT DIVE Spa Controls Pump Diagrams LW 524 Pump 1 Air Control Pump 1 REV 012018 ...
Page 61: ...59 DO NOT DIVE Spa Controls Pump Diagrams LW 715 Pump 1 REV 012018 Pump 1 Air Control ...
Page 75: ......