background image

www.prolight.co.uk

Stage Par CZ 120 RGBA

  

User Manual

9

Master/slave mode:

To set the master unit, press the 

“MENU”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to show  

NASt

 

on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to 

choose  

ON

  choose  

OFF

. Press the 

“ENTER”

 button to confirm the setting.  

Then select your desired program.  
To set the other units in slave mode, press the 

“MENU”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to 

show 

SLNd

 on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons 

to choose either 

SL 1

SL 2

. Press the 

“ENTER”

 button to confirm the setting. The unit will now run 

in sequence with the master unit. To exit out of any of the above options, press the 

“MENU”

 button. 

Please ensure that all slave units are set to the same DMX channel mode as the master unit.

Show mode:

To access the show modes, press the 

“MENU”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to show  

SHNd

 on the LED display. Now press the 

“ENTER”

 button and use the 

“UP”

 and 

“DOWN”

 buttons to 

choose between 

SH 0

 ~ 

SH 9

.  

To change the speed of the selected program press the 

“ENTER” 

button and then use the 

“UP”

 and 

“DOWN”

 buttons to select any value from  

SP00

 ~ 

SP99

.  

Press the 

“ENTER” 

button to confirm the setting. 

In  

SH 0

  you are able to set a specific static colour. When in  

SH 0

  press the 

“ENTER” 

button and 

then use the 

“UP”

 and 

“DOWN”

 buttons to go through the static colours. Press the 

“ENTER” 

button to 

confirm the setting. 
To exit out of any of the above options, press the 

“MENU”

 button.

Operating instructions

Show 0

Colour macros (Colour 1 - Colour 64)

Show 1

3 colour fade (red, green, blue)

Show 2

4 colour fade (red, green, blue, amber)

Show 3 

3 colour fade (red, green, blue) with amber @ 100%

Show 4

4 colour change (red, green, blue, amber)

Show 5 

10 colour change (red, green, blue, amber, yellow, magenta, cyan, orange, lime green, lilac)

Show 6

Red continuous fade in/out

Show 7

Green continuous fade in/out

Show 8

Blue continuous fade in/out

Show 9

Amber continuous fade in/out

Summary of Contents for Stage Par CZ 120 RGBA

Page 1: ...Order codes LEDJ192 Black Housing LEDJ192P Polished Housing Stage Par CZ 120 RGBA User Manual...

Page 2: ...f in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment...

Page 3: ...g is available in black or polished aluminium and a gel frame holder is supplied enabling diffusion filters to be fitted 1 x 120W quad colour LED RGBA Manually adjustable beam angle 15 35 13 800 Lux 2...

Page 4: ...of the par can The latch can then be moved forwards or backwards smoothly allowing the operator to select the beam angle required between 15 and 35 using the markers provided as a guide Release the s...

Page 5: ...r DMX address setting O N O F F N A S t Master setting S L 1 S L 2 S L N d Slave setting b L N d L A S t d N S t No DMX signal S N O O F A S t S P d Dimmer speed setting C U r V Dimming curves L I N...

Page 6: ...0 0 2 5 5 g r E E 0 0 0 2 5 5 b L U E 0 0 0 2 5 5 A N b E 0 0 0 2 5 5 S t r 0 0 0 0 2 5 5 d I N N F H r s Fixture hours t t E N p Fixture temperature A U t O t E S t Auto test U U E r Software versio...

Page 7: ...To exit out of any of the above options press the MENU button 4 channel mode Channel Value Function CH1 000 255 Red dimmer 0 100 CH2 000 255 Green dimmer 0 100 CH3 000 255 Blue dimmer 0 100 CH4 000 25...

Page 8: ...192 Colour 48 193 196 Colour 49 197 200 Colour 50 201 204 Colour 51 205 208 Colour 52 209 212 Colour 53 213 216 Colour 54 217 220 Colour 55 221 224 Colour 56 225 228 Colour 57 229 232 Colour 58 Channe...

Page 9: ...d use the UP and DOWN buttons to show SHNd on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose between SH 0 SH 9 To change the speed of the selected program press t...

Page 10: ...oo Smooth or FAst Fast Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button LED backlight To access the LED backlight setting press the MENU butt...

Page 11: ...ture To exit out of any of the above options press the MENU button Fixture hours To access the fixtures usage time press the MENU button and use the UP and DOWN buttons to show FHrS on the LED display...

Page 12: ...ng all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data tran...

Page 13: ...cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin...

Page 14: ...e started Please note Caution should be used when power linking other fixtures to the Stage Par CZ 120 RGBA as the power consumption of other fixtures will vary Fixtures fitted with lamps often requir...

Page 15: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of materi...

Page 16: ...www prolight co uk Stage Par CZ 120 RGBA User Manual 16...

Reviews: