Setting the DMX address:

The DMX mode enables the use of a universal DMX controller. Each fixture requires a “start address” 
from 1- 512. A fixture requiring one or more channels for control begins to read the data on the channel 
indicated by the start address. For example, a fixture that occupies or uses 7 channels of DMX and was 
addressed to start on DMX channel 100, would read data from channels: 100, 101, 102, 103, 104, 
105 and 106. Choose a start address so that the channels used do not overlap. E.g. the next unit in  
the chain starts at 107.

DMX 512:

DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent 
fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. 
DMX data is sent as serial data that travels from fixture to fixture via the DATA “IN” and DATA “OUT”  
XLR terminals located on all DMX fixtures (most controllers only have a data “out” terminal).

DMX linking:

DMX is a language allowing all makes and models of different manufactures to be linked together  
and operate from a single controller, as long as all fixtures and the controller are DMX compliant.  
To ensure proper DMX data transmission, when using several DMX fixtures try to use the shortest  
cable path possible. The order in which fixtures are connected in a DMX line does not influence the  
DMX addressing. For example; a fixture assigned to a DMX address of 1 may be placed anywhere in  
a DMX line, at the beginning, at the end, or anywhere in the middle. When a fixture is assigned a  
DMX address of 1, the DMX controller knows to send DATA assigned to address 1 to that unit,  
no matter where it is located in the DMX chain.

DATA cable (DMX cable) requirements (for DMX operation):

This fixture can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. 
Your unit requires either a standard 3-pin or 5-pin XLR connector for data input/output,  
see images below.

 
 
 
Also remember that DMX cable must be daisy chained and cannot be split.

DMX setup

Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight Concepts dealers.
Please quote:

CABL10 – 2m

CABL11 – 5m

CABL12 – 10m

3-Pin:

CABL185 – 2m

CABL187 – 5m

CABL188 – 10m

5-Pin:

Summary of Contents for Stage Par CZ 120 RGBA

Page 1: ...Order codes LEDJ192 Black Housing LEDJ192P Polished Housing Stage Par CZ 120 RGBA User Manual...

Page 2: ...f in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment...

Page 3: ...g is available in black or polished aluminium and a gel frame holder is supplied enabling diffusion filters to be fitted 1 x 120W quad colour LED RGBA Manually adjustable beam angle 15 35 13 800 Lux 2...

Page 4: ...of the par can The latch can then be moved forwards or backwards smoothly allowing the operator to select the beam angle required between 15 and 35 using the markers provided as a guide Release the s...

Page 5: ...r DMX address setting O N O F F N A S t Master setting S L 1 S L 2 S L N d Slave setting b L N d L A S t d N S t No DMX signal S N O O F A S t S P d Dimmer speed setting C U r V Dimming curves L I N...

Page 6: ...0 0 2 5 5 g r E E 0 0 0 2 5 5 b L U E 0 0 0 2 5 5 A N b E 0 0 0 2 5 5 S t r 0 0 0 0 2 5 5 d I N N F H r s Fixture hours t t E N p Fixture temperature A U t O t E S t Auto test U U E r Software versio...

Page 7: ...To exit out of any of the above options press the MENU button 4 channel mode Channel Value Function CH1 000 255 Red dimmer 0 100 CH2 000 255 Green dimmer 0 100 CH3 000 255 Blue dimmer 0 100 CH4 000 25...

Page 8: ...192 Colour 48 193 196 Colour 49 197 200 Colour 50 201 204 Colour 51 205 208 Colour 52 209 212 Colour 53 213 216 Colour 54 217 220 Colour 55 221 224 Colour 56 225 228 Colour 57 229 232 Colour 58 Channe...

Page 9: ...d use the UP and DOWN buttons to show SHNd on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose between SH 0 SH 9 To change the speed of the selected program press t...

Page 10: ...oo Smooth or FAst Fast Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button LED backlight To access the LED backlight setting press the MENU butt...

Page 11: ...ture To exit out of any of the above options press the MENU button Fixture hours To access the fixtures usage time press the MENU button and use the UP and DOWN buttons to show FHrS on the LED display...

Page 12: ...ng all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data tran...

Page 13: ...cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin...

Page 14: ...e started Please note Caution should be used when power linking other fixtures to the Stage Par CZ 120 RGBA as the power consumption of other fixtures will vary Fixtures fitted with lamps often requir...

Page 15: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of materi...

Page 16: ...www prolight co uk Stage Par CZ 120 RGBA User Manual 16...

Reviews: