Ledj Stage Par CZ 120 RGBA User Manual Download Page 3

www.prolight.co.uk

Stage Par CZ 120 RGBA

  

User Manual

3

Stage Par CZ 120 RGBA

FUSE:

T2A 250V

100-240V~50/60Hz

POWER CONSUMPTION: 150W

POWER INPUT

POWER OUTPUT

SAFETY

EYE

DMX OUTPUT

DMX INPUT

MENU

ENTER

DOWN

UP

www.prolight.co.uk

01

02

07

03

04

06

05

08

09

Product overview & technical specifications

The CZ 120 RGBA Stage Par is powered by a high output 120W quad-colour COB (chip-on-board) RGBA LED, ideal 

for stage productions, concerts or theatre applications. The beam angle can be manually adjusted between 15° 

and 35° and on-board controls offer 4 different dimmer curve options, whilst the 5-pin DMX and powerCON input/

output allow for easy connections, adding to the host of professional features on these fixtures. The traditional par 

can style housing is available in black or polished aluminium and a gel frame holder is supplied enabling diffusion 

filters to be fitted.

• 1 x 120W quad-colour LED (RGBA)
• Manually adjustable beam angle: 15° - 35°
• 13,800 Lux @ 2m (full on)
• 3kHz refresh rate
• DMX channels: 4/7 or 11 selectable
• Manual and master/slave modes  

plus built-in programs

• 0-100% dimming and variable strobe
• Supplied with hanging bracket
• 4 push button menu with LED display
• PowerCON input/output
• 5-Pin XLR input/output
• Fan cooled
• Filter frame included

Stage Par CZ 120 RGBA

Specifications

Stage Par CZ 120

Power consumption

150W

Power supply

100~240V, 50/60Hz

Fuse

T2A 250V

Dimensions

405 x 302 x 444mm

Weight

3.9kg

Order codes

LEDJ192 - Black Housing
LEDJ192P - Polished Housing

01 - LED display
02 - Function buttons
03 - 5-Pin XLR input
04 - 5-Pin XLR output
05 - PowerCON input
06 - PowerCON output
07 - Fuse T2A 250V
08 - Earth point
09 - Safety eye

In the box: 

1 x fixture, 

1 x filter frame, 

1 x power cable 

& 1 x user manual

Summary of Contents for Stage Par CZ 120 RGBA

Page 1: ...Order codes LEDJ192 Black Housing LEDJ192P Polished Housing Stage Par CZ 120 RGBA User Manual...

Page 2: ...f in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment...

Page 3: ...g is available in black or polished aluminium and a gel frame holder is supplied enabling diffusion filters to be fitted 1 x 120W quad colour LED RGBA Manually adjustable beam angle 15 35 13 800 Lux 2...

Page 4: ...of the par can The latch can then be moved forwards or backwards smoothly allowing the operator to select the beam angle required between 15 and 35 using the markers provided as a guide Release the s...

Page 5: ...r DMX address setting O N O F F N A S t Master setting S L 1 S L 2 S L N d Slave setting b L N d L A S t d N S t No DMX signal S N O O F A S t S P d Dimmer speed setting C U r V Dimming curves L I N...

Page 6: ...0 0 2 5 5 g r E E 0 0 0 2 5 5 b L U E 0 0 0 2 5 5 A N b E 0 0 0 2 5 5 S t r 0 0 0 0 2 5 5 d I N N F H r s Fixture hours t t E N p Fixture temperature A U t O t E S t Auto test U U E r Software versio...

Page 7: ...To exit out of any of the above options press the MENU button 4 channel mode Channel Value Function CH1 000 255 Red dimmer 0 100 CH2 000 255 Green dimmer 0 100 CH3 000 255 Blue dimmer 0 100 CH4 000 25...

Page 8: ...192 Colour 48 193 196 Colour 49 197 200 Colour 50 201 204 Colour 51 205 208 Colour 52 209 212 Colour 53 213 216 Colour 54 217 220 Colour 55 221 224 Colour 56 225 228 Colour 57 229 232 Colour 58 Channe...

Page 9: ...d use the UP and DOWN buttons to show SHNd on the LED display Now press the ENTER button and use the UP and DOWN buttons to choose between SH 0 SH 9 To change the speed of the selected program press t...

Page 10: ...oo Smooth or FAst Fast Press the ENTER button to confirm the setting To exit out of any of the above options press the MENU button LED backlight To access the LED backlight setting press the MENU butt...

Page 11: ...ture To exit out of any of the above options press the MENU button Fixture hours To access the fixtures usage time press the MENU button and use the UP and DOWN buttons to show FHrS on the LED display...

Page 12: ...ng all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data tran...

Page 13: ...cable adaptor must be used The diagram below details the correct cable conversion 5 pin XLR female Pin 1 GND screen Pin 2 Signal Pin 3 Signal Pin 4 N C Pin 5 N C 3 pin XLR female Pin 1 GND screen Pin...

Page 14: ...e started Please note Caution should be used when power linking other fixtures to the Stage Par CZ 120 RGBA as the power consumption of other fixtures will vary Fixtures fitted with lamps often requir...

Page 15: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of materi...

Page 16: ...www prolight co uk Stage Par CZ 120 RGBA User Manual 16...

Reviews: