The Lectra/San EC Type I MSD can be connected to
two marine toilets.  However, the two toilets must be
in close proximity to:

1. Reduce the pressure requirement to move waste

through the connecting hose.

2. To decrease the possibility of untreated sewage

remaining in the lines.

The Lectra/San EC Treatment Tank should be lo-
cated midway between the two toilets.  The maxi-
mum distance from either toilet to the tank should
not exceed six feet.

A kit is available for field conversion to dual toilet
operation:

Lectra/San EC Dual Control Component part
#LSTEDC (for 12 V units):

1. Control Indicator Panel with ribbon cable at-

tached.

2. Salt Feed Tank complete.

INSTALLATION

1. Adding second toilet - Install Lectra/San and

first toilet per manual, then add second toilet by
connecting discharge line to the opposite side of
the tank.  Remove the plug to allow connections.
(See Figures #11A and #11B)

2. Electric toilet - Installations with two electric

toilets must be wired to work independent from
the Control Indicator Panels.  Contact Raritan
Customer Service for instructions.

3. Mounting - Each toilet should be installed within

six feet of Lectra/San EC.

4. Control Indicator Panel - The Dual Control

Indicator Panel attaches directly to the Lectra/
San EC circuit board, the original Control Indica-
tor Panel connects inline using the special con-
nector attached to the dual control ribbon (See
Fig. #12A).

OPERATION

Indicator/LED lights will indicate operation on both
panels when any toilet is in use.  DO NOT activate
"Push to Flush" button if another toilet is in use.

A Salt Feed Tank should be installed in each toilet's
intake hose if operating in fresh or brackish water.
The flow control for each Salt Feed Tank must be set
independently.

USING THE LECTRA/SAN EC SYSTEM WITH TWO MARINE HEADS

NOTE:  Single push button operation of LST/EC or toilet cannot be installed in this application.

FIG. #11A  Lectra/San EC Mounted Below the Waterline

FIG. #11B  Lectra/San EC Mounted Above the Waterline

Control #1

Control #2

Ribbon
Cable

Ribbon
Cable

FIG. #12A

Dual  Control  Cable (#31-406)

Circuit Breaker

Battery

Lectra/San

Treatment

 Unit

less than 6'

<

less than 6'

>

<

>

Summary of Contents for EC

Page 1: ... 10 It is designed and approved to treat waste for overboard discharge inareasthatarenotdeclaredaNo Dischargezoneby the U S Environmental Protection Agency The total system is made up of three basic parts TheControlIndicatorPanel Beginsthetreatment cycle and can also be connected to flush an electric toilet at the same time single toilet application Dimensions 4 1 2 H x 2 3 4 W x 1 D The Treatment...

Page 2: ...cted to the Lectra San EC for single button operation Periodically inspect the unit for leaks and check for loose plumbing and electrical connections WARNING If the toilet is wired on its own circuit or manually operated make sure power to Lectra San EC is OFF prior to cleaning and or winterizing CLEANING WARNING DO NOT activate the Lectra San EC during this procedure Discharge seacocks must be in...

Page 3: ...ment Unit Cover and pull out the electrode pack Rinse with fresh water and clean with a stiff non wire brush Empty any remaining water from the tank RECOMMISSIONING START UP 1 Reconnect hoses and open seacocks 2 RemovethethreefusesfromtheControlModule locatedonthetopoftheTreatmentTank Mark Fig 4 Lectra San EC with vented loop below waterline Below Waterline Installation Requires Vented Loop Betwee...

Page 4: ...ow the water line Control Indicator Panel 1 Locate an area in the head compartment where the indicator lights will be readily visible 2 Using template provided mark the cutout for the panel Do not cut outside of template markings 3 Route ribbon cable between panel and Lectra San EC Treatment Unit Secure ribbon cable with cable holders every 18 inches taking care not to puncture the insulation or c...

Page 5: ...e Treatable Day 576 Maximum Roll Pitch Angle 30 Maximum Temperature Exposure 120 F Maximum Total Flush Volume 1 5 Gallons Flush Atlantes owners Use deodorant tank for salt mixture reduce concentrate ratio by 1 2 ELECTRIC WIRING WARNING Danger of electric shock Be sure to disconnect power 1 Run supply wire to Positive and Negative terminals using specification table for wire size and circuit breake...

Page 6: ...n EC Circuit Board Lectra San EC Switch Panel POS NEG Fig 9 BAT Isolated Coil Solenoid Relay Electric Toilet Battery JQC203 JQC101 12 18 AWG Purple Yellow Fuses Ckt Breakers Orange macerator motor Brown Red electrode plate Orange mixer motor Ribbon Cable Clamp Ribbon Cable Purple Yellow Location of circuit boards Lectra San EC Electronic Control Atlantes Toilet Indicator Panel Atlantes Circuit Boa...

Page 7: ...o treat each flush the unit must be activated at each flush F5 Clean dirty electrode plates or replace F6 Replace the B Fuse Test the electrodes Replace if necessary TROUBLESHOOTING PROBLEM A When button is pushed nothing happens system inoperative B Check Fuse light is on C Low salt light on The low salt indicator is lit when the electronics in the Lectra San EC control board determines that not ...

Page 8: ... 2 12 31 114 Cover Hold Down Nut 10 32 18 13 31 115 Treatment Tank 14 31 122 Intake Plug 15 32 5000 Electrode Pack 12 VDC 15 33 5000 Electrode Pack 24 VDC 15 34 5000 Electrode Pack 32 VDC 16 31 112 Cover Gasket 17 31 108 Macerator Set Screw 8 32x3 16 S S 18 31 107 Macerator Impeller 19 31 101W Treatment Cover Inc items 7 20 and 21 20 31 104 Crossover Plug 21 31 102 Motor Shaft Seal 2 22 32 101 Mac...

Page 9: ...S Hex Head Machine Screw 4 14 1118 1 4 External Tooth Washer 5 15 1226B 1 4 20 S S Hex Head Nut 4 16 31 476 Nylon Spacer Washer 2 17 ED1N4002 Diode 2 20 F31 480 Nylon Stand Offs PCB Supports 4 EXPLODED PARTS VIEW OF CONTROL MODULE Item Part No Description 21 F069 Gray Fiber Flat Washer 22 F31 478 Threaded Rod 1 4 20 x 2 Brass 23 5 16 24 Nut 4 24 5 16 Lockwasher 4 25 6 32 Screw 26 31 464 Bracket 30...

Page 10: ...work independent from the Control Indicator Panels Contact Raritan Customer Service for instructions 3 Mounting Eachtoiletshouldbeinstalledwithin six feet of Lectra San EC 4 Control Indicator Panel The Dual Control Indicator Panel attaches directly to the Lectra SanECcircuitboard theoriginalControlIndica tor Panel connects inline using the special con nector attached to the dual control ribbon See...

Page 11: ...Treatment Tank Connection will be made during Step 9 B Treatment Tank 1 Remove terminal block 31 131 save screws nuts and washers for mounting Control Module in Step 5 Discard terminal block see Fig 11C Disconnect negative battery wire to electrode pack 2 Remove mounting straps They will need to be routed through the slots on new Control Module Fig 12B 3 Remove two screws from lid as shown in Fig ...

Page 12: ...nce with the manufacturer s recommended installation instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BYIMPLICATI...

Reviews: