background image

11

RED to POS. (+)
lug on cover

Purple

ORANGE to macerator motor
POS. (+) lead

Brown

Yellow

POS. (+) lead from mixer
motor (ORANGE)

(2) BLACK wires w/crimp

connectors - To BLACK NEG.(-)

leads

 

from motors

BLACK to NEG. (-)

lug on cover

31-404
Ribbon Cable
Connection

10 pin (orange) connector

32-402

To Battery POS.(+)

31-460

To Battery NEG.(-)

Figure #13B

Discard

To battery
Negative

Save

Figure #12B

CONVERSION OF LECTRA/SAN  TO LECTRA/SAN  EC INSTALLATION INSTRUCTIONS

Figure #11C

Parts included in package:
Control Module (32-402, 33-402 or 34-402) 
 -  Mounts
directly  to  treatment unit

Control Cover (31-460)  -  Installs over Control Module
Control Indicator Panel (31-403)  -  Replaces old
Control unit

Ribbon Cable (31-404)  -  Connects  Control  Module To
Control Indicator Panel - 12' long.

Tools needed  -  3/8", 5/16", and 7/16" nut drivers, blade
and Phillips head screw drivers, wire cutters, #14 AWG
strippers and crimpers and small adjustable wrench.

INSTALLATION

Before beginning conversion disconnect battery leads
and be sure power to unit is OFF.
If old control unit was flush mounted you will need to
cover the opening.  If the new control indicator panel will
be located in the same opening see the panel template for
cutout purposes.

A. Existing Control Unit  -  Remove and discard existing
Control Unit (32-2000, 33-2000 or 34-2000) and Control
Cable (31-210), reroute positive (+) wire from terminal E
on the relay to the Treatment Tank.  Connection will be
made during Step 9.

B. Treatment Tank
1. Remove terminal block (31-131), save screws, nuts

and washers for mounting Control Module in Step 5.
Discard terminal block (see Fig. #11C).  Disconnect
negative battery wire to electrode pack.

2. Remove mounting straps.   They will need to be routed

through the slots on new Control Module (Fig. #12B).

3. Remove two screws from lid as shown in Fig. #12B

and reinstall them in place of the screws removed in
Step 1.  The two holes left by removing the screws will
be used for attaching the Control Module in Step 5.

4. Connect RED (+) and BLACK (-) wires from new

Control Module to POSITIVE (+) and NEGATIVE
(-) lugs on cover (Electrode Pack).  Polarity must be
the same (see Fig. #13B).

5. Mount Control Module (32-402, 33-402 or 34-402)

using the screws from Step 1.

6. Cut the BLACK NEGATIVE (-) wire terminals off

both the mixer and macerator motors.  Strip 3/8" of
wire and attach to crimp connectors on the black leads
from Control Module (see Fig. #13B).

7. Cut the POSITIVE (+) wire terminal off the macerator

(larger) motor and strip 3/8" of wire.  Attach to
ORANGE POSITIVE (+) lead with crimp connector
from fuse block (see Fig. #13B).

8. Connect mixer (smaller) motor POSITIVE (+) lead to

Fuse A on fuse block using the existing terminal (see
Fig. #13B).

9. Connect POSITIVE (+) and NEGATIVE (-) wires to

the front side of Control Module (see Fig. #12B).

10.Reinstall mounting straps through slots on Control

Module and resecure them (Fig. #12B).

Control Indicator Panel  -  See mounting and electric
wiring section.
Install Cover on Control Module

Slots for

Mounting Straps

Summary of Contents for EC

Page 1: ... 10 It is designed and approved to treat waste for overboard discharge inareasthatarenotdeclaredaNo Dischargezoneby the U S Environmental Protection Agency The total system is made up of three basic parts TheControlIndicatorPanel Beginsthetreatment cycle and can also be connected to flush an electric toilet at the same time single toilet application Dimensions 4 1 2 H x 2 3 4 W x 1 D The Treatment...

Page 2: ...cted to the Lectra San EC for single button operation Periodically inspect the unit for leaks and check for loose plumbing and electrical connections WARNING If the toilet is wired on its own circuit or manually operated make sure power to Lectra San EC is OFF prior to cleaning and or winterizing CLEANING WARNING DO NOT activate the Lectra San EC during this procedure Discharge seacocks must be in...

Page 3: ...ment Unit Cover and pull out the electrode pack Rinse with fresh water and clean with a stiff non wire brush Empty any remaining water from the tank RECOMMISSIONING START UP 1 Reconnect hoses and open seacocks 2 RemovethethreefusesfromtheControlModule locatedonthetopoftheTreatmentTank Mark Fig 4 Lectra San EC with vented loop below waterline Below Waterline Installation Requires Vented Loop Betwee...

Page 4: ...ow the water line Control Indicator Panel 1 Locate an area in the head compartment where the indicator lights will be readily visible 2 Using template provided mark the cutout for the panel Do not cut outside of template markings 3 Route ribbon cable between panel and Lectra San EC Treatment Unit Secure ribbon cable with cable holders every 18 inches taking care not to puncture the insulation or c...

Page 5: ...e Treatable Day 576 Maximum Roll Pitch Angle 30 Maximum Temperature Exposure 120 F Maximum Total Flush Volume 1 5 Gallons Flush Atlantes owners Use deodorant tank for salt mixture reduce concentrate ratio by 1 2 ELECTRIC WIRING WARNING Danger of electric shock Be sure to disconnect power 1 Run supply wire to Positive and Negative terminals using specification table for wire size and circuit breake...

Page 6: ...n EC Circuit Board Lectra San EC Switch Panel POS NEG Fig 9 BAT Isolated Coil Solenoid Relay Electric Toilet Battery JQC203 JQC101 12 18 AWG Purple Yellow Fuses Ckt Breakers Orange macerator motor Brown Red electrode plate Orange mixer motor Ribbon Cable Clamp Ribbon Cable Purple Yellow Location of circuit boards Lectra San EC Electronic Control Atlantes Toilet Indicator Panel Atlantes Circuit Boa...

Page 7: ...o treat each flush the unit must be activated at each flush F5 Clean dirty electrode plates or replace F6 Replace the B Fuse Test the electrodes Replace if necessary TROUBLESHOOTING PROBLEM A When button is pushed nothing happens system inoperative B Check Fuse light is on C Low salt light on The low salt indicator is lit when the electronics in the Lectra San EC control board determines that not ...

Page 8: ... 2 12 31 114 Cover Hold Down Nut 10 32 18 13 31 115 Treatment Tank 14 31 122 Intake Plug 15 32 5000 Electrode Pack 12 VDC 15 33 5000 Electrode Pack 24 VDC 15 34 5000 Electrode Pack 32 VDC 16 31 112 Cover Gasket 17 31 108 Macerator Set Screw 8 32x3 16 S S 18 31 107 Macerator Impeller 19 31 101W Treatment Cover Inc items 7 20 and 21 20 31 104 Crossover Plug 21 31 102 Motor Shaft Seal 2 22 32 101 Mac...

Page 9: ...S Hex Head Machine Screw 4 14 1118 1 4 External Tooth Washer 5 15 1226B 1 4 20 S S Hex Head Nut 4 16 31 476 Nylon Spacer Washer 2 17 ED1N4002 Diode 2 20 F31 480 Nylon Stand Offs PCB Supports 4 EXPLODED PARTS VIEW OF CONTROL MODULE Item Part No Description 21 F069 Gray Fiber Flat Washer 22 F31 478 Threaded Rod 1 4 20 x 2 Brass 23 5 16 24 Nut 4 24 5 16 Lockwasher 4 25 6 32 Screw 26 31 464 Bracket 30...

Page 10: ...work independent from the Control Indicator Panels Contact Raritan Customer Service for instructions 3 Mounting Eachtoiletshouldbeinstalledwithin six feet of Lectra San EC 4 Control Indicator Panel The Dual Control Indicator Panel attaches directly to the Lectra SanECcircuitboard theoriginalControlIndica tor Panel connects inline using the special con nector attached to the dual control ribbon See...

Page 11: ...Treatment Tank Connection will be made during Step 9 B Treatment Tank 1 Remove terminal block 31 131 save screws nuts and washers for mounting Control Module in Step 5 Discard terminal block see Fig 11C Disconnect negative battery wire to electrode pack 2 Remove mounting straps They will need to be routed through the slots on new Control Module Fig 12B 3 Remove two screws from lid as shown in Fig ...

Page 12: ...nce with the manufacturer s recommended installation instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BYIMPLICATI...

Reviews: