background image

4

above the waterline at maximum heel to prevent
siphoning.

 MOUNTING

Treatment Unit

Location:  The Treatment Tank should be within six
feet of the toilet, with the tank located at the same
level or lower than the toilet's discharge.   If the tank
is at the same level, or slightly above the toilet, a
vented loop must be installed between the toilet and
the Treatment Tank (see  Fig. #2).   If  the  treatment
unit must be mounted more than a few inches higher
than the toilet, contact Raritan Customer Service.

WARNING:  DO  NOT  locate  in  an  area  where
ambient temperature exceeds 120

o

 F.

Securing Treatment Tank:

1. Make mounting frame (Fig. #5).

2. Secure mounting frame using suitable fasteners.

3. Use 3/4" mounting straps to secure tank to frame

(see Fig. #5).  A 3/8" rubber pad (available at a
hardware store) placed under the tank will help to
reduce vibration and noise.

   PLUMBING

Use high quality, smooth interior 1 1/2" I.D. sanita-
tion hose to avoid odor problems, available from
Raritan by the foot (part #SH).  Discharge from the
toilet enters either side of the Treatment Tank and
exits from the fitting on top of the lid.

1. Connect Lectra/San EC to marine toilet per Fig-

ures #2, #3 or #4.  Do not route hose into dips or
valleys and avoid 90

o  

fittings where possible.

2. Use teflon tape or nonpermanent thread sealing

compound on threaded PVC fittings and connec-
tions.

3. Determine the orientation of the discharge elbow

provided before gluing with PVC Cement.

4. Double clamp all hose fittings below the water-

line.

Control Indicator Panel

1. Locate an area in the head compartment where

the indicator lights will be readily visible.

2. Using template provided, mark the cutout for the

panel.  Do not cut outside of template markings.

3. Route ribbon cable between panel and Lectra/

San EC Treatment Unit.  Secure ribbon cable
with cable holders every 18 inches, taking care
not to puncture the insulation or crimp the cable.

4. Plug in the ribbon connection (Fig. #6) to indica-

tor panel and mount panel using four #6 screws.

Salt Feed Tank:  (Salt Feed Tank is needed when the
boat will be in fresh water/brackish water.)

1. Assemble the salt feed tank per Fig. #7A.

2. Locate Salt Feed Tank within 6 feet of toilet and

at same level as bowl.  Secure tank.  Make sure
the tank is accessible for refilling.

3. Attach the T-check valve and tubing to the Salt

Feed Tank.

4. Attach T-check valve in the  intake line (suction)

of the  toilet.  Remove  the  ball  and  spring  in
Raritan PHII models (Fig. #7).

5. In a separate container, combine five pounds of

rock salt with two gallons of warm water and
allow to dissolve overnight.  Pour off water into
tank (this is a saturated salt solution).  The salt
remaining in the bottom may be used the next
time.

2

1

To remove, spread wings
and cable will pop out of
connector.

Wings in extended position
while making connection

When cable is pushed into connector wings
will snap into proper locking position.

T Check Valve (incl. w/Salt Feed System)

Fig. #7 Raritan PHII with Salt Feed Tank

Remove Ball and Spring

Fig. #6  - Ribbon Connector

Fig. #5

1"x1"

14 1/8"

7"

Mounting Straps*

Wooden frame
surrounding tank*

Vibration isolation pad
beneath tank (Optional)*

3

* not included

Summary of Contents for EC

Page 1: ... 10 It is designed and approved to treat waste for overboard discharge inareasthatarenotdeclaredaNo Dischargezoneby the U S Environmental Protection Agency The total system is made up of three basic parts TheControlIndicatorPanel Beginsthetreatment cycle and can also be connected to flush an electric toilet at the same time single toilet application Dimensions 4 1 2 H x 2 3 4 W x 1 D The Treatment...

Page 2: ...cted to the Lectra San EC for single button operation Periodically inspect the unit for leaks and check for loose plumbing and electrical connections WARNING If the toilet is wired on its own circuit or manually operated make sure power to Lectra San EC is OFF prior to cleaning and or winterizing CLEANING WARNING DO NOT activate the Lectra San EC during this procedure Discharge seacocks must be in...

Page 3: ...ment Unit Cover and pull out the electrode pack Rinse with fresh water and clean with a stiff non wire brush Empty any remaining water from the tank RECOMMISSIONING START UP 1 Reconnect hoses and open seacocks 2 RemovethethreefusesfromtheControlModule locatedonthetopoftheTreatmentTank Mark Fig 4 Lectra San EC with vented loop below waterline Below Waterline Installation Requires Vented Loop Betwee...

Page 4: ...ow the water line Control Indicator Panel 1 Locate an area in the head compartment where the indicator lights will be readily visible 2 Using template provided mark the cutout for the panel Do not cut outside of template markings 3 Route ribbon cable between panel and Lectra San EC Treatment Unit Secure ribbon cable with cable holders every 18 inches taking care not to puncture the insulation or c...

Page 5: ...e Treatable Day 576 Maximum Roll Pitch Angle 30 Maximum Temperature Exposure 120 F Maximum Total Flush Volume 1 5 Gallons Flush Atlantes owners Use deodorant tank for salt mixture reduce concentrate ratio by 1 2 ELECTRIC WIRING WARNING Danger of electric shock Be sure to disconnect power 1 Run supply wire to Positive and Negative terminals using specification table for wire size and circuit breake...

Page 6: ...n EC Circuit Board Lectra San EC Switch Panel POS NEG Fig 9 BAT Isolated Coil Solenoid Relay Electric Toilet Battery JQC203 JQC101 12 18 AWG Purple Yellow Fuses Ckt Breakers Orange macerator motor Brown Red electrode plate Orange mixer motor Ribbon Cable Clamp Ribbon Cable Purple Yellow Location of circuit boards Lectra San EC Electronic Control Atlantes Toilet Indicator Panel Atlantes Circuit Boa...

Page 7: ...o treat each flush the unit must be activated at each flush F5 Clean dirty electrode plates or replace F6 Replace the B Fuse Test the electrodes Replace if necessary TROUBLESHOOTING PROBLEM A When button is pushed nothing happens system inoperative B Check Fuse light is on C Low salt light on The low salt indicator is lit when the electronics in the Lectra San EC control board determines that not ...

Page 8: ... 2 12 31 114 Cover Hold Down Nut 10 32 18 13 31 115 Treatment Tank 14 31 122 Intake Plug 15 32 5000 Electrode Pack 12 VDC 15 33 5000 Electrode Pack 24 VDC 15 34 5000 Electrode Pack 32 VDC 16 31 112 Cover Gasket 17 31 108 Macerator Set Screw 8 32x3 16 S S 18 31 107 Macerator Impeller 19 31 101W Treatment Cover Inc items 7 20 and 21 20 31 104 Crossover Plug 21 31 102 Motor Shaft Seal 2 22 32 101 Mac...

Page 9: ...S Hex Head Machine Screw 4 14 1118 1 4 External Tooth Washer 5 15 1226B 1 4 20 S S Hex Head Nut 4 16 31 476 Nylon Spacer Washer 2 17 ED1N4002 Diode 2 20 F31 480 Nylon Stand Offs PCB Supports 4 EXPLODED PARTS VIEW OF CONTROL MODULE Item Part No Description 21 F069 Gray Fiber Flat Washer 22 F31 478 Threaded Rod 1 4 20 x 2 Brass 23 5 16 24 Nut 4 24 5 16 Lockwasher 4 25 6 32 Screw 26 31 464 Bracket 30...

Page 10: ...work independent from the Control Indicator Panels Contact Raritan Customer Service for instructions 3 Mounting Eachtoiletshouldbeinstalledwithin six feet of Lectra San EC 4 Control Indicator Panel The Dual Control Indicator Panel attaches directly to the Lectra SanECcircuitboard theoriginalControlIndica tor Panel connects inline using the special con nector attached to the dual control ribbon See...

Page 11: ...Treatment Tank Connection will be made during Step 9 B Treatment Tank 1 Remove terminal block 31 131 save screws nuts and washers for mounting Control Module in Step 5 Discard terminal block see Fig 11C Disconnect negative battery wire to electrode pack 2 Remove mounting straps They will need to be routed through the slots on new Control Module Fig 12B 3 Remove two screws from lid as shown in Fig ...

Page 12: ...nce with the manufacturer s recommended installation instructions or standard industry procedures physical abuse to or misuse of this product This warranty also does not cover damages to equipment caused by fire flood external water excessive corrosion or Act of God 3 ANY EXPRESS WARRANTY NOT PROVIDED HEREIN AND ANY REMEDY FOR BREACH OF CONTRACT WHICH BUT FOR THIS PROVISION MIGHT ARISE BYIMPLICATI...