Le Maitre Ltd.
Wireless SQP User Manual
25
No response from unit Tilt lock-out engaged
Position on a level surface and re-enable unit.
DMX signal not received Check DMX controller and test cables.
Control not synced
Re-sync to controller and check link strength.
See 5.4
Gas
leaking
when
canister is installed
Firing pin too high.
Reduce firing pin height. Refer to Maintenance
instructions.
No spark detected
Spark electrode dirty
Refer to Maintenance instructions in 7.3
Electrode
connection
problem
Check connections from spark electrode to
ignition coil. Check resistance between spark
electrode and module output (HT lead).
Spark detection circuit
error but spark
is
present.
Remove all canisters
. Disable spark detection.
Arm and check the spark electrode inside flue to
see if spark is generated between electrodes.
If spark runs along one of the electrodes to
machine body refer to 7.3.
Ignitor electrodes out of
alignment or otherwise
damaged
Contact Le Maitre.
Machine disarms
unexpectedly
Tilt lock-out engaged
Position the machine on a level, protect it from
vibration and re-enable unit.
Control panel buttons
pressed while armed
This is a safety feature. Do not press any buttons
while machine is armed. Disarm Wireless SQP
before approaching.
Er1 displays in COBRA
mode
Contamination of
motherboard/COBRA
module interface
Open top lid. Unplug red COBRA module from
motherboard (careful not to damage the
antenna wire). Clean the interface header pins
on both boards from both sides of the board
(preferably with pressurised air). Reassemble.
If you encounter issue not listed, advised solution does not help and/or you have any questions please
contact Le Maitre Ltd.