background image

3

FOR EQUIPMENT THAT CONNECTS TO THE POWER MAINS

22. CAUTION: If the power cord of the device is equipped with an earthing contact, then it must be connected to an outlet with a protective ground. 

Never deactivate the protective ground of a power cord. 

23. If the equipment has been exposed to strong fluctuations in temperature (for example, after transport), do not switch it on immediately. Moisture 

and condensation could damage the equipment. Do not switch on the equipment until it has reached room temperature. 

24. Before connecting the equipment to the power outlet, first verify that the mains voltage and frequency match the values specified on the equip-

ment. If the equipment has a voltage selection switch, connect the equipment to the power outlet only if the equipment values and the mains power 

values match. If the included power cord or power adapter does not fit in your wall outlet, contact your electrician. 

25. Do not step on the power cord. Make certain that the power cable does not become kinked, especially at the mains outlet and/or power adapter 

and the equipment connector. 

26. When connecting the equipment, make certain that the power cord or power adapter is always freely accessible. Always disconnect the equip-

ment from the power supply if the equipment is not in use or if you want to clean the equipment. Always unplug the power cord and power adapter 

from the power outlet at the plug or adapter and not by pulling on the cord. Never touch the power cord and power adapter with wet hands. 

27. Whenever possible, avoid switching the equipment on and off in quick succession because otherwise this can shorten the useful life of the 

equipment.

28. IMPORTANT INFORMATION: Replace fuses only with fuses of the same type and rating. If a fuse blows repeatedly, please contact an authorised 

service centre. 

29. To disconnect the equipment from the power mains completely, unplug the power cord or power adapter from the power outlet. 

30. If your device is equipped with a Volex power connector, the mating Volex equipment connector must be unlocked before it can be removed. 

However, this also means that the equipment can slide and fall down if the power cable is pulled, which can lead to personal injuries and/or other 

damage. For this reason, always be careful when laying cables. 

31. Unplug the power cord and power adapter from the power outlet if there is a risk of a lightning strike or before extended periods of disuse.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN

CAUTION: 

Never remove the cover, because otherwise there may be a risk of electric shock.  There are no 

user serviceable parts inside. Have repairs carried out only by qualified service personnel.

The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated 

“dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electrical shock. 

The exclamation mark within an equilateral triangle is intended to alert the user to the presence of important operating and 

maintenance instructions.

CAUTION – HIGH VOLUME LEVELS WITH AUDIO PRODUCTS!

This equipment is intended for professional use. Therefore, commercial use of this equipment is subject to the respectively applicable national accident 

prevention rules and regulations. As a manufacturer, Adam Hall is obligated to notify you formally about the existence of potential health risks. 

Hearing damage due to high volume and prolonged exposure: When in use, this product is capable of producing high sound-pressure levels (SPL) 

that can lead to irreversible hearing damage in performers, employees, and audience members.

For this reason, avoid prolonged exposure to volumes in excess of 90 dB. 

To prevent possible hearing damage, avoid listening at high volume levels over long periods of time.

Even exposure to short bursts of loud noise can result in hearing loss. Please keep the volume constantly at a comfortable level.

DE

SICHERHEITSHINWEISE 

1. Lesen Sie diese Anleitung bitte sorgfältig durch. 

2. Bewahren Sie alle Informationen und Anleitungen an einem sicheren Ort auf. 

3. Befolgen Sie die Anweisungen. 

4. Beachten Sie alle Warnhinweise. Entfernen Sie keine Sicherheitshinweise oder andere Informationen vom Gerät. 

5. Verwenden Sie das Gerät nur in der vorgesehenen Art und Weise. 

6. Verwenden Sie ausschließlich stabile und passende Stative bzw. Befestigungen (bei Festinstallationen). Stellen Sie sicher, dass Wandhalterungen 

ordnungsgemäß installiert und gesichert sind. Stellen Sie sicher, dass das Gerät sicher installiert ist und nicht herunterfallen kann. 

7. Beachten Sie bei der Installation die für Ihr Land geltenden Sicherheitsvorschriften. 

8. Installieren und betreiben Sie das Gerät nicht in der Nähe von Heizkörpern, Wärmespeichern, Öfen oder sonstigen Wärmequellen. Sorgen Sie dafür, 

dass das Gerät immer so installiert ist, dass es ausreichend gekühlt wird und nicht überhitzen kann.

9. Platzieren Sie keine Zündquellen wie z.B. brennende Kerzen auf dem Gerät. 

10. Lüftungsschlitze dürfen nicht blockiert werden. 

11. Betreiben Sie das Gerät nicht in unmittelbarer Nähe von Wasser. Bringen Sie das Gerät nicht mit brennbaren Materialien, Flüssigkeiten oder 

Gasen in Berührung. Direkte Sonneneinstrahlung vermeiden! 

12. Sorgen Sie dafür, dass kein Tropf- oder Spritzwasser in das Gerät eindringen kann. Stellen Sie keine mit Flüssigkeit gefüllten Behältnisse wie 

Vasen oder Trinkgefäße auf das Gerät. 

13. Sorgen Sie dafür, dass keine Gegenstände in das Gerät fallen können. 

14. Betreiben Sie das Gerät nur mit dem vom Hersteller empfohlenen und vorgesehenen Zubehör. 

15. Öffnen Sie das Gerät nicht und verändern Sie es nicht. 

16. Überprüfen Sie nach dem Anschluss des Geräts alle Kabelwege, um Schäden oder Unfälle, z. B. durch Stolperfallen zu vermeiden. 

17. Achten Sie beim Transport darauf, dass das Gerät nicht herunterfallen und dabei möglicherweise Sach- und Personenschäden verursachen kann.

18. Wenn Ihr Gerät nicht mehr ordnungsgemäß funktioniert, Flüssigkeiten oder Gegenstände in das Geräteinnere gelangt sind, oder das Gerät ander-

weitig beschädigt wurde, schalten Sie es sofort aus und trennen es von der Netzsteckdose (sofern es sich um ein aktives Gerät handelt).  

Summary of Contents for AM 8 LDAM8

Page 1: ...1 AM 8 8 CHANNEL AUTOMATIC MIXER LDAM8 USER S MANUAL BEDIENUNGSANLEITUNG MANUEL D UTILISATION MANUAL DE USUARIO INSTRUKCJA OBS UGI MANUALE D USO...

Page 2: ...tto secondo elevati standard qualitativi che garantiscono un funzionamento regolare per molti anni Per questo motivo LD Systems con il suo nome e la pluriennale esperienza rappresenta un azienda produ...

Page 3: ...intended to alert the user to the presence of important operating and maintenance instructions CAUTION HIGH VOLUME LEVELS WITH AUDIO PRODUCTS This equipment is intended for professional use Therefore...

Page 4: ...rgf ltig 31 Entfernen Sie Netzkabel und Netzadapter aus der Steckdose bei Gefahr eines Blitzschlags oder wenn Sie das Ger t l nger nicht verwenden CAUTION RISK OF ELECTRIC SHOCK DO NOT OPEN ACHTUNG En...

Page 5: ...e d s que vous n utilisez pas l appareil pendant un certain temps ou si vous d sirez nettoyer l appareil Pour ce faire tirez toujours sur la fiche elle m me ou sur le bloc secteur lui m me ne tirez ja...

Page 6: ...encienda inmediatamente La conden saci n o la humedad podr an da ar el equipo Deje que el equipo alcance la temperatura ambiente antes de encenderlo 24 Antes de conectar el cable el ctrico a la toma d...

Page 7: ...mo e wykona tylko autoryzowany personel specjalistyczny 19 Do czyszczenia urz dzenia stosowa such ciereczk 20 Przestrzega obowi zuj cych w danym kraju przepis w dotycz cych usuwania odpad w Podczas u...

Page 8: ...icare tutti i cavi per evitare danni o incidenti ad esempio per inciampo 17 Durante il trasporto assicurarsi che il dispositivo non possa cadere e causare possibili danni a cose e o persone 18 Se il d...

Page 9: ...x ouverts vous vitez ainsi d accumuler les bruits de fond les parasites et effets de filtre en peigne ind sirables ce qui am liore l intelligibilit de la voix D s que le niveau du signal d entr e pass...

Page 10: ...w czone bezg o nie bez trzask w Dzi ki temu podczas przekazu na danym kanale dodatkowe odg osy sprz enia zwrotne oraz niechciane efekty dzia ania filtra grzebieniowego pochodz ce z pozosta ych otwart...

Page 11: ...Stromnetz angeschlossen und eingeschaltet ist FR La LED Power s allume lorsque l appareil est correctement reli au secteur et sous tension ES El LED POWER se ilumina si el equipo est encendido y corre...

Page 12: ...1 8 0 60dB in steps of 1dB master volume 2 bit master volume 1 2 0 60 dB in steps of 1dB manual threshold level 1 bit 0 60dB in steps of 4dB Example V 01 2020202020202020 3030 0A AF79 FR R glages RS...

Page 13: ...ous Windows avec le logiciel de contr le AUTOMIX8 Reliez le mixeur automatique AM8 au port Ethernet l aide d un c ble r seau CAT 5 ES El puerto RS 485 permite controlar de forma remota el mezclador au...

Page 14: ...n 24 CH7 Input short to ground activates channel Pin 12 CH7 Output 3 3V when channel is activated Pin 25 CH8 Input short to ground activates channel Pin 13 CH8 Output 3 3V when channel is activated 14...

Page 15: ...ATION MANUELLE BEDIENUNG UTILISATION MANUELLE OPERACI N MANUAL OBS UGA R CZNA FUNZIONAMENTO MANUALE 18 17 19 21 20 22 17 INPUT GAIN CH 1 CH 8 EINGANGSVORVERST RKUNG CH 1 CH 8 PR AMPLIS CH 1 CH 8 GANAN...

Page 16: ...orio para cambiar la sensibilidad de entrada ver tabla LED DE ESTADO L NEA MICRO Tenga en cuenta que si no pulsa el control giratorio en 10 segundos no se introducir ning n cambio y el LED dejar de pa...

Page 17: ...E MASTER 1 2 SUMMENLAUTST RKE MASTER 1 2 VOLUME BUS MASTER 1 2 NIVEL DE MEZCLA MASTER 1 2 SUMA G O NO CI MASTER 1 2 VOLUME DI MISSAGGIO MASTER 1 2 EN Encoder for setting the total volume of the line o...

Page 18: ...wierdzi zmian ustawie przez naci ni cie przycisku MASTER W przypadku przypisania obu kana w wyj ciowych Master 1 i Master 2 do jednej grupy kana w patrz GRUPY KANA W mo na jednocze nie ustawi g o no o...

Page 19: ...ne Status LED wird das Ausgangs Signal des entsprechenden Line Ausgangs Master 1 oder Master 2 mit Line Pegel ausgegeben z B f r den Line Eingang einer Endstufe Leuchtet die Status LED nicht wird das...

Page 20: ...a e il LED smette di lampeggiare STATUS LED MASTER 1 2 LED flashing red ready to switch LED MASTER 1 green Volume setting Master 1 LED MASTER 2 green Volume setting Master 2 STATUS LED LINE LED flashi...

Page 21: ...progowej od 50 dB do 10 dB w celu automatycznej aktywacji kana w wej ciowych dioda stanu nr 32 wieci si na czerwono Poziom warto ci progowej nale y ustawi tak aby ha as otoczenia nie w czy automatyczn...

Page 22: ...rosso eventualmente ruotare la manopola THRESHOLD fino a quando il LED di stato AUTO MANUAL lampeggia in rosso e premere brevemente la manopola THRESHOLD Se il tasto non viene premuto entro una decina...

Page 23: ...alit di funzionamento premere innanzitutto la manopola THRESHOLD uno dei 3 LED AUTO MANUAL MASTER o LOCK ora lampeggia in rosso eventualmente ruotare la manopola THRESHOLD fino a quando il LED di stat...

Page 24: ...AM8 automatic mixer DE Inbetriebnahme Verwenden Sie f r die Verkabelung des AM8 Automatik Mixers ausschlie lich symmetrische Kabel Um Sch den am Audio System durch R ckkopplungen etc zu vermeiden stel...

Page 25: ...e w komfortowy spos b Automatyczny mikser AM8 zosta domy lnie ustawiony na czu o odpowiedni dla sygna u mikrofonowego na wszystkich wej ciach audio Ponadto 48 V zasilanie phantom jest w czone oprogram...

Page 26: ...nexi n en cascada A un sistema de audio se pueden conectar en cascada hasta 16 mezcladores autom ticos AM8 de LD Systems Al conectar en cascada los mezcladores autom ticos AM8 mediante el puerto LINK...

Page 27: ...me l adresse IP de l AM8 est r gl e automatiquement en usine sur la valeur 192 168 1 88 le port utilis sur l ordinateur doit poss der une adresse IP diff rente voir la fen tre de Windows Propri t s d...

Page 28: ...1366 x 768 y co necte el mezclador autom tico AM8 mediante un cable LAN CAT 5 al puerto Ethernet del ordenador Como por defecto la direcci n IP del mezclador autom tico AM8 es 192 168 1 88 deber asign...

Page 29: ...prowadzania ustawie i sterowania za pomoc oprogramowania AUTOMIX8 ka demu automatycznemu mikserowi nale y przypisa indywidualny adres IP W tym celu ka dy z mikser w nale y po czy z oprogramowaniem z o...

Page 30: ...d sir en cliquant sur l adresse IP correspondante puis cliquez sur le champ bleu OK et entrez comme d habitude votre nom d utilisateur et votre mot de passe ES Es posible tener conectado un nico mezc...

Page 31: ...INESTRA PRINCIPALE DEL SOFTWARE 1 2 3 4 5 6 9 9 11 10 12 13 14 16 18 15 17 22 20 19 21 8 7 1 CHANNELS EN Overview of the input channels CHANNEL 1 8 and the line outputs MASTER 1 2 DE bersicht der Eing...

Page 32: ...mantenimiento HOLD TIME el bloqueo de los controles PANEL LOCK el establecimiento del equipo como maestro o esclavo DEVICE MODE el n mero m ximo de canales abiertos MAX OPEN CH la direcci n IP DEVICE...

Page 33: ...band parametric equalizer of the output channels Master 1 and 2 single click with the left mouse button DE Grafische Darstellung der Equalizer Einstellung und Schaltfl che zum Aufrufen der 5 Band Par...

Page 34: ...ES El color amarillo en ACTIVE indica el canal de entrada activo Si un canal no est activado se mostrar WAITING sobre fondo gris Mediante la funci n Prioridad el canal permanece siempre activo PL Wyr...

Page 35: ...b szarym w przypadku dezaktywacji IT Pulsanti di attivazione e visualizzazione dell alimentazione phantom 48 V dei canali d ingresso Facendo clic sul pulsante PHANTOM si attiva e disattiva l alimentaz...

Page 36: ...e curseur ES Ajuste la ganancia de los canales de salida Master 1 y 2 mediante el rat n haga clic y arrastre PL Ustawi wzmocnienie wyj cia wyj liniowych Master 1 i 2 za pomoc myszy komputera klikn prz...

Page 37: ...de los canales de entrada 1 a 8 Haga clic en el bot n de un canal para configurar el ecualizador El color de fondo cambiar a amarillo PL Przycisk i wy wietlany obszar otwieraj cy pi ciopasmowy parame...

Page 38: ...r zur ckzustellen klicken Sie auf RESET Dieser Vorgang ist nicht umkehrbar FR Pour r initialiser l galiseur et le filtre passe haut cliquez sur RESET Cette r initialisation n est pas annulable ES Para...

Page 39: ...En el ecualizador gr fico pueden cambiarse a la vez la frecuencia y la ganancia Para ello haga clic en uno de los 5 puntos y arr strelo PL Wzmocnienie 15 danego pasma cz stotliwo ci nast puje przez b...

Page 40: ...epresentation of the EQ curve is used for quick and clear overview of the equalizer settings Frequency and Gain can be changed at the same time using the 5 points in the graphic representation of the...

Page 41: ...rektora d wi ku mo e zosta indywidualnie dobrana w zakresie od 20 Hz do 20 000 Hz W tym celu nale y u y pola cz stotliwo ci do wprowadzenia danej warto ci cz stotliwo ci lub przycisk w strza ek znajdu...

Page 42: ...QUALIZER DARSTELLUNG REPR SENTATION GRAPHIQUE DE LA COURBE D GALISATION GRAFICZNE ODWZOROWANIE KOREKTORA D WI KU EQUALIZZATORE GRAFICO EN The graphical representation of the EQ curve is used for quick...

Page 43: ...aga clic seleccione un valor y haga clic de nuevo PL Ustawienie czasu ataku w zakresie od 1 ms do 2 s Przesun kursor myszy na pole czasu ataku klikn lewym przyciskiem myszy wybra dan warto i ponownie...

Page 44: ...ondant D s qu un canal est assign une sortie le bouton passe en bleu CHANNEL OPEN s il ne l est pas le bouton est gris CHANNEL CLOSED ES Con la matriz de audio del mezclador autom tico AM8 puede envia...

Page 45: ...sch ein 0 2000ms Der Kanal bleibt so f r die Dauer der eingestellten Haltezeit auch nach Verstummen des Audio Signals aktiviert Ein anderer Kanal kann also erst nach Ablauf der Haltezeit aktiviert wer...

Page 46: ...finir le nombre maximal de canaux d entr e pouvant tre activ s simultan ment choisissez le dans le menu local puis cliquez sur OK Dans la fen tre alors ouverte cliquez de nouveau sur OK ES Establezca...

Page 47: ...w posiadaj cych r ne uprawnienia dost powe chronione has em i wymagaj ce zalogowania tj admin i user U ytkownik admin administrator ma uprawnienia dost powe do wszystkich opcji menu programu a u ytkow...

Page 48: ...nostka g wna W przypadku kaskadowania maksymalnie 16 automatycznych mikser w AM8 za pomoc interfejsu LINK IN LINK OUT znajduj cego si na tylnym panelu urz dzenia patrz punkt 14 PRZY CZA ELEMENTY OBS U...

Page 49: ...utente possono essere salvate direttamente sul computer e recuperate successivamente Questi file di dati contengono tutte le impostazioni relative ad esempio all equalizzatore al limitatore all instra...

Page 50: ...branej grupy zostanie wtedy wyr niony kolorem tym IT Per raggruppare i canali di ingresso e uscita in un gruppo di canali fare clic su uno dei 5 gruppi di canali per elaborarli GROUP 1 5 Il pulsante d...

Page 51: ...der entsprechenden Funktionen werden nun gelb hervorgehoben Beispiel Die Mute Funktion ist f r die Eingangskan le 1 bis 3 die in der Gruppe 1 GROUP 1 zusammengefasst sind aktiviert Schalten Sie nun Ka...

Page 52: ...kOhm Phantom Power Mic Inputs 48 V individually switchable Input Sensitivity Line 20 dBu LINE Input Impedance 8 4 kOhm Maximum Line Input Level 20 dBu Analogue Line Outputs 2 Master 1 Master 2 Analog...

Page 53: ...dBu Line Ausg nge analog 2 Master 1 Master 2 Line Ausgangsanschl sse analog Klemmblock symmetrisch Ausgangsimpedanz 100 Ohm Maximaler Line Ausgangspegel 20 dBu Line Ausg nge digital 1 AES EBU Line Au...

Page 54: ...FR R f rence Mod le LDAM8 Type de Produit Mixeur automatique Type num rique Nombre d entr es sorties 8 entr es 2 sorties Convertisseurs A N et N A 24 bits Fr quence d chantillonnage 96 kHz Fonctions D...

Page 55: ...s individuellement en mode param trique ou Shelve 15 dB Q r glable 0 3 20 fr quence d intervention 20 Hz 20 kHz r glable par pas de 1 Hz Bypass Reset Gain maximal sur les entr es 60 dB Att nuation fon...

Page 56: ...CONTROL D Sub de 25 pines N m ximo de equipos en cascada 16 Toma el ctrica Conector IEC Alimentaci n el ctrica 110 240 VAC 50 60 Hz Consumo 60 W Rango operativo de temperaturas 0 a 50 C Humedad relat...

Page 57: ...e mikro fonowe symetryczne kostki zaciskowe Czu o wej ciowa mikrofon 8 7 mV Impedancja wej ciowa mikrofon 2 k Zasilanie phantom wej mikrofo nowych 48 V prze czane indywidualnie Czu o wej ciowa wej cie...

Page 58: ...aksymalny czas wstrzymania w trybie aktywnej funkcji Automix 2 s IT Nome del modello LDAM8 Tipo di prodotto Mixer automatico Tipo Digitale Configurazione 8 ingressi 2 uscite Convertitore AD DA 24 bit...

Page 59: ...e AUTOMIX8 per LDAM8 Compatibilit Windows Vista 7 8 Porta necessaria RS 485 Ethernet Ingressi parametri EQ LINE MIC attivabile PRIORITY PHANTOM MUTE GAIN Ingressi HPF 35 150 Hz Ingressi EQ Parametrico...

Page 60: ...t werden FR GARANTIE FABRICANT LIMITATION DE RESPONSABILIT Nos conditions actuelles de garantie et de limitation de responsabilit sont disponibles l adresse suivante http www adamhall com media shop d...

Page 61: ...ewentualne sprawdzenie uzgodnionych umownie warunk w utylizacji urz dze Niniejszy produkt nie mo e by utylizowany razem z innymi odpadami przemys owymi IT MANUFACTURER S WARRANTY LIMITATION OF LIABILI...

Page 62: ...62...

Page 63: ...63...

Page 64: ...64 Adam Hall GmbH Daimlerstrasse 9 61267 Neu Anspach Germany Tel 49 0 6081 9419 0 Fax 49 0 6081 9419 1000 web www adamhall com e mail mail adamhall com WWW LD SYSTEMS COM REV 01...

Reviews: