Technical specifications

Actuators

Descriptions

8310-2420 Series

Input voltage 

(for LED electronic board)

24V DC

Current draw 

(for LED electronic board)

110 mA @ 24 VDC

Contact rating

3A @ 30 VDC

Lumina red

14.8 lumens, 1600 mW

Lumina green

3.8 lumens, 330 mW

Sounder

3200 ± 300 Hz @ 85 dB

Relay contact

1 x Form C

Mounting

4 x #12 wood screws with anchors

Construction

Flame-resistant black ABS (insert-translucent ABS)

Finish

Attractive pebble finish

Dimensions

6 1/2” x 6 1/2” x 2” (165 mm x 165 mm x 51 mm)

E-strike

Descriptions

8310-2420 Series

Voltage

24 DC

Current Draw

150 mA maximum @ 24 VDC

Static strength

1000 lbs.

Dynamic strength

50-ft. lbs.

Mode

Field selectables

Fail safe/fail secure

Mechanical adjustment

Strike body/faceplate

Operation

DC-silent

Duty

Continuous

Dimensions (body)

3 3/8” x 1 7/8” x 1 7/32” (86 mm  x 47 mm x 31 mm)

Transformer

Descriptions

8310-2420 Series

Input voltage

120V AC

Output voltage

24V AC @ 60 Hz

Class

B2

Power

50 VA

DPS Switch

Descriptions

8310-2420 Series

Power max.

3.0 W

Electrical configuration

SPDT

Suggested Wiring

22AWG

Gap distance max.

0.75”

Operation at a glance

When the exterior PUSH TO OPEN button is pressed it will trigger the PBTN input on its electrical board causing its N.O. 

relay contact to send a momentary closure to the outside PUSH TO OPEN on the restroom kit allowing the door to swing 

open. When the interior PUSH TO LOCK button is pressed, it will trigger the PBTN input on its electrical board, causing its 

N.O. relay contact to send a momentary closure to inside PUSH TO LOCK , causing the restroom kit to lock the restroom 

and switch the electrical board colors from green to red. The inside PUSH TO OPEN button is wired directly to inside PUSH 

TO OPEN on the restroom kit. When pressed, the restroom will unlock and the door will swing open. The restroom can also 

be unlocked by opening the door from the inside, which will break the door contact circuit, causing the restroom kit to reset 

and unlock the door. The electrical board will switch back to green, signaling that the restroom is now vacant.

Summary of Contents for 8310-2420

Page 1: ...for Door to Close vinyl decal 1 9 Door locked when red unlocked when green black vinyl sign 1 10 Door occupied when red vacant when green black vinyl sign 1 11 E strike with 3 faceplates and hardware...

Page 2: ...B2 Power 50 VA DPS Switch Descriptions 8310 2420 Series Power max 3 0 W Electrical configuration SPDT Suggested Wiring 22AWG Gap distance max 0 75 Operation at a glance When the exterior PUSH TO OPEN...

Page 3: ...onic board in place 1e Place the diffuser insert inside the flush enclosure making sure the mounting screw holes on the diffuser insert and the flush enclosure align For Push to Open switches a Use th...

Page 4: ...Safe mode when Mode Selector is pointing to FS Fail Lock mode when Mode Selector is pointing to Fail Lock Set Screw Mode Selector Mode Selector Set Screw L Note The products are intended to be instal...

Page 5: ...r The transformer should only be installed OUTSIDE of the Power Supply Cabinet per all National Electric Code NEC NFPA 70 requirements along with local code requirements and it should be kept in close...

Page 6: ...ently off Do not wire the primary terminals of the transformer until the secondary terminals are connected first The supplied transformer will have its secondary terminals wired to the terminals red w...

Page 7: ...ls in cabinet via wire access hole RED GREEN BLUE Connected to 24V DC from the VDC terminals in the cabinet via wire access hole REM LOC RELAY SPEAKER Wired to the Inside Push to Open terminals in the...

Page 8: ...0 50 seconds The second option d 1 flashing will be how long to wait before activating relay 2 0 15 seconds The third option H 2 flashing will be how long relay 2 will be activated for 0 50 seconds T...

Page 9: ...2 3 ON DP RED GREEN BLUE REM LOC RELAY SPEAKER See the diagrams below for the dip switch functionalities Enable Dip Switch Bank Idle COL Dip Switch Bank Switch number Description Switch number Descrip...

Page 10: ...K THIS DOOR WAIT FOR DOOR TO CLOSE Place sign on the door inside the restroom at eye level INSIDE THE RESTROOM POWER SUPPLY 6 12 24 VDC SMP3 24V OPEN CLSD CLSD OPEN SW1 SW2 6V OPEN OPEN 12V SW1 SW2 AC...

Page 11: ...shown connecting the Push to Open switch to the Push to Open terminals Com Rem PBTN N O Pwr AC DC Com Rem PBTN N O Pwr AC DC IMPORTANT Ensure wiring polarity is consistent from Relay 3 to each remote...

Page 12: ...osing the door or after pushing Push to Lock Logic Module not in Mode 7 Change Logic Module to Mode 7 and ensure all mode 7 settings are set as shown in the instructions No power to the strike Ensure...

Page 13: ...he solenoid releases This can be caused by too much stack pressure on the door pressing on the strike Electric Strike itself is set to Fail Secure rather than Fail Safe Follow the electric strike inst...

Page 14: ...is latching then the door may not fully latch If this occurs the source of the pressure force needs to be removed so that the door can fully close This can be caused by too much stack pressure preven...

Page 15: ...inals Take a jumper wire and touch the screw heads of the PBTN and terminals the actuators wires are hooked up to If the unit acts as if the actuator was actually pushed then either the actuator was w...

Page 16: ...ion DPS switch not closing contact Wiring issue Verify wiring is correct to Power Supply Relay Cabinet and DPS wires fully connected Incorrect mounting Mounting gap should be no more than 3 4 between...

Page 17: ...7 Cabinet base template 9 8 6...

Page 18: ......

Page 19: ......

Page 20: ......