- 29 -
SINGLE WEIGHING
In this case
the lorry is weighed once
: the weight of the empty lorry is used as preset tare; the
value may be entered on the spot or retrieved from the lorry database.
Function not available if net functions are disabled (see parameter
in section
INFO MENU
).
SINGLE WEIGHING WITHOUT USING THE DATABASE
The lorry goes onto the weighbridge.
Press PTARE, enter the weight of the empty lorry (preset tare) using the numerical keypad, confirm
with ENTER.
The display shows the weight of the material loaded onto the lorry (net weight).
Press IN if the lorry is entering (the material will be unloaded).
Press OUT if the lorry is leaving (the material will be loaded).
The display shows the weight of the material preceded by the letter
for “Unloaded” if unloaded,
letter
for “Loaded” if loaded.
The instrument saves the weighed value in the memory and sends it for printing.
The instrument automatically goes back to showing the gross weight.
SINGLE WEIGHING USING THE DATABASE
The lorry goes onto the weighbridge.
Press DB the display shows
.
With the numerical keypad enter the database index associated to the lorry (the weight of the empty
lorry must have already been entered previously as preset tare in the database, see section
LORRY
DATABASE
).
Press ENTER.
The instrument applies the preset tare read from the database and shows the weight of the material
loaded onto the lorry (net weight).
Press IN if the lorry is entering (the material will be unloaded).
Press OUT if the lorry is leaving (the material will be loaded).
The display shows the weight of the material preceded by the letter
for “Unloaded” if unloaded,
letter
for “Loaded” if loaded.
The instrument saves the weighed value in the memory and sends it for printing.
The instrument automatically goes back to showing the gross weight.
NOTES:
operation with single weighing is only possible with the net weight. The totals are updated
every time a weighing is completed. To display, print or delete the totals, see sections
TOTALS
and
PRINTING EXAMPLES
. The conditions that allow a new weighing to be carried out can be set (see
section
WEIGHINGS STORAGE AND PRINTING CONDITIONS
).