9
4. Speed internal parameter settings
4.1. How to use
In order to enter the temperature internal parameter setting mode, the user must introduce the
password. To do that, follow these steps:
4.
Press
for 3 seconds.
-
The screen will display
Lc
-
The speed area of the screen will display the password value
5.
Use
to choose the required password value. See password values below.
6.
Press
to enter the value.
If the password is
incorrect
, the display will return to the home screen.
If the password is
correct
, the display will show the temperature internal parameter settings mode.
Then:
4.
Press
to modify each parameter.
5.
Use
to choose desired value.
6.
Press
for 3 seconds to return to the home screen.
If no key is pressed for 1 minute, the display will return to the home screen.
4.2. Internal parameter tables
INDICATOR
NAME
FUNCTION DESCRIPTION
FACTORY VALUE
Lc
Password
The password to modify the parameters in this
table is
Lc = 3
0
Pd
Proportional
gain
Speed proportional gain.
(1
~
100)
10
Id
Integral
coefficient
Speed integral coefficient.
(1
~
100)
5
InT
Acceleration
time
Time it takes for the motor to accelerate to the
new set speed.
(1
~
60)
10
dET
Deceleration
time
Time it takes for the motor to decelerate to the
new set speed.
(1
~
60)
10
SdL
Speed lower
limit
Minimum speed setting
(20
~
500)
20
SdH
Speed upper
limit
Maximum speed setting
(20
~
500)
300