G2F-POR101 Filter Cart Operation Procedure Manual
Part # NPOR101-2016
ISO 9001:2008 REGISTERED QMS
Page 14 of 16
Rev # 4.4
Jan. 2016
Copyright © 2016
G2F ELEMENT CHANGE PROCEDURE
This is intended as a guide to the changing of the element only and any other
requirements set out by law and or company must be followed relating to lock
out policy or procedures.
Follow all lock out procedures as required by government and
company.
Turn off power switch to the off position.
Remove power cord from power outlet.
Allow Portable Filter Cart too sufficiently cool down in order to
prevent possible burn injuries.
Slowly loosen T- Handle (by turning counter clock wise) on G2F
Housing.
Remove G2F Lid placing it on a clean location avoiding placement
such as to add contamination to lid.
Clean G2F Lid and do not remove O-rings that are under the T-
handle and G2F Lid, merely inspect and replace if necessary.
Unwrap G2F Element from Vacuum sealed vapour barrier; remove
plastic disposal bag from center core of element. This will be used
to dispose of spent element upon removal.
Place the new G2F Element down on clean surface with the top
side down (as to not to add contamination to bottom side of
element prior to changing).