G2F-POR101 Filter Cart Operation Procedure Manual
Part # NPOR101-2016
ISO 9001:2008 REGISTERED QMS
Page 10 of 16
Rev # 4.4
Jan. 2016
Copyright © 2016
Turn the power switch to the on position briefly in order to check
the direction of rotation of the motor. Looking at it from the
pump’s side of the motor it should turn counter clockwise as
indicated by the red arrow on the motor fan cover. If it is turning
the wrong way, change the phases of the wiring in the
connection box on top of the motor, the switch box or the
electrical panel.
Upon proper rotation of the motor turn the Filter Cart to the on
position until the pressure gauge shows a pressure of 3 bar.
Let the Filter Cart installation run for about 10 to 15 minutes,
until all the air is pumped out and the filter housing unit is
completely saturated with oil.
Monitor Filter Cart for any possible leaks.
If leaks occur shut down immediately by turning power switch to
the off position to investigate and rectify.
When using a brand new G2F Element, the bar pressure gauge
will rise until the G2F Element is thoroughly saturated with oil,
then the pressure gauge will decrease to give you a true reading.
Should the suction gauge indicate high values, the inlet
hose or the suction filter is blocked/obstructed and needs
to be cleaned. If on the other hand this suction gauge
shows extremely low values, air is taken in.
Should after start up and the G2F element is fully saturated with
oil and if the pressure gauge rises into the red, adjust the Relief
Valve accordingly to lower the pressure back into the green
section of the System pressure gauge
(to 3 bar) .