TECHNICAL PARAMETERS
PARAMETER
UNIT
VALUE
Outside measurement
mm
610
(L)
x 230
(W)
x 420
(H)
Weight
kg
27
Suction filter
1
80 Mesh
G2F-filter housing
1
G2F-LP350 type
Normal flow
l/min
4
Maximum tank capacity
liters
1,800
Hose connection
JIC
Inlet -6 JIC
Outlet -6 JIC
Maximum oil temperature
C
80
Range of oil viscosity
cSt
9 – 220
Working pressure
Element change out pressure
bar
3
5
Feed
Volts
1~/110V
(1~/230V)
<1~/220V/>
[3~/230V/400V]
{3~/220V/440V}
Motor
Hz/kW
60Hz/0,37
kW
(50Hz/0,25 kW)
<60Hz/0,37kW>
[50Hz/0,37kW]
{60Hz/0,43kW}