Sentinel Plus Press Brake Guarding System Operation Manual
LS-CS-M-073
Page 53
Original Language Version: 1.04
Released: 19/07/2017
Note:
The Sentinel Plus system will not allow a value to be entered which is outside of
the allowable range for that parameter. The valid range of values is displayed
next to the parameter’s name in the Parameter screen (ignore the units). If an
attempt is made to exceed the valid range, an
Entry out of range
message is
displayed, and the value will not be saved.
8.2
User Menu
The user menu does not have access control, and can be accessed by anyone.
8.2.1
Parameter 0
–
Buzzer On/Off
This parameter sets the behaviour of the buzzer.
•
ENABLED
. The default setting is for the buzzer to sound on every button press.
•
DISABLED
. The buzzer will never sound.
Use the ▲▼ buttons to navigate the options. Changes can be abandoned at any time by
pressing the
button. When the desired option has been selected, press the
ENTER
button, the value will be written into the panel’s non-volatile memory, and the system will
return to the parameter list.
8.2.2
Parameter 1
–
Special Tools Mode
Special Tools mode can be enabled/disabled by this user selectable parameter. This
parameter has two options.
•
DISABLED
. The default setting is for Special Tools mode to be disabled.
•
ENABLED
. Enables Special Tools mode as described in
Section 3.9.1
.
The operator can tell when Special Tools mode is enabled by the
STM
symbol
in the
Sensor window, as shown in
Figure 8-4
.
BL
STM
Figure 8-4: Special Tools Mode Enabled
Use the ▲▼ buttons to navigate the options. Changes can be abandoned at any time by
pressing the
button. When the desired option has been selected, press the
ENTER
button, the value will be written into the panel’s non-volatile memory, and the system will
return to the parameter list.
8.2.3
Parameter 2
–
Thermal Compensation Mode
Thermal Compensation mode can be enabled/disabled by this user selectable parameter.
This parameter has two options.
•
DISABLED
. The default setting is for Thermal Compensation mode to be disabled.
•
ENABLED
. Enables Thermal Compensation mode as described in
Section 3.9.2
.
The operator can tell when Thermal Compensation mode is enabled by the
TCM
symbol
in
the Sensor window, as shown in
Figure 8-4
.