MACHINE
INFO
SYSTEM
INFO
SYSTEM INFORMATION
0000
Comm status
Connected
HMI type
Sentinel Plus
HMI version
HMI v1.09.00
Kernel version
Ax2.12.00
Application
hmi__104
FPGA version
Approx. slow point
2mm
MSD
13mm
BLR version
BL
Table 5-5: Info Screen, System Information
5.7.2
Machine Information
Machine Information is displayed by pressing the
MACHINE INFO
menu button in the Info
screen.
•
Stop Time
. Measured by the PGS-3 each time the beam is stopped.
•
Stop Distance
. Measured by the PGS-3 each time the beam is stopped.
•
Stop Time Limit
. The maximum allowable stopping time for the machine, and only
applies when light curtain guarding is active (stopping performance is normally
indicated by the stopping distance). If this limit is exceeded, an emergency stop is
initiated, and an overrun test is performed.