18
1.
Open the second basic tower
9
and firmly snap in the joint in the
folding part. Attach it at an angle of 180° to the first basic tower.
Secure the joints with spring clips
15
.
2.
Snap in the access deck
24
at the second cross-rung from below of
the upper basic tower.
3.
To complete the working platform, install 3 guardrails
16
, toe boards
25
and end toe boards
26
.
1.
Open the second basic tower
9
and firmly snap in the joint in the
folding part. Attach it at an angle of 180° to the first basic tower.
Secure the joints with spring clips
15
.
During assembly and dismantling, system decks or scaffolding
planks according to DIN 4420-3 (minimum dimensions 28 x 4.5 x
220 cm) must be installed as auxiliary decks at maximum height
intervals of 2.0 m. These auxiliary decks provide a safe footing
for assembly and dismantling, and must be removed again after
assembly. Each platform must be completely boarded.
Further assembly
Tower model 623
Further assembly
Tower model 624