mc²56 MKII Technical Manual
V5.10.2/1
60
Chapter 2: Installation
Installing the Control Surface
Grounding
Although operator protection is guaranteed (the control surface is connected via the Power Connectors to the
ground of the power supply system) it is best to establish an additional ground for EMC reasons.
1.
Fasten the grounding cable to the
CASE
grounding bolt (M5 x 12) on the rear panel using a Torx T25
driver:
Warning
The control surface must be on the same potential as all other system devices/modules.
For Scandinavian countries,
ALWAYS
use a grounded mains connection, to prevent the device from being
grounded through Ethernet or other signal connections.
Grounding of Audio Interfaces
For compliance with AES3, digital interfaces (connected to the
) should be connected to a field ground.
Summary of Contents for mc256 MKII
Page 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Page 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Page 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Page 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...