Chapter 1: Technical Overview
Hardware Components
Local I/O
The mc
2
56 MKII control surface includes an integrated local I/O board. This provides dedicated connections for
local devices such as monitoring, metering, talkback and headphones.
All local I/O connections are accessed from the control surface rear panel:
The local I/O provides:
·
16 Line In
- wired to 2 x DSub (female).
Note that
Line In 16
can be fed from the integrated talkback mic preamp, according to the
positions set for the Local I/O.
·
16 Line Out
:
o
Line Out 1-8 - wired to 8 x XLR (male). By default, these outputs are routed from the CRM 1 monitor
output.
o
Line Out 9-16 - wired to 1 x DSub (male).
·
8 AES3 In
- wired to 2 x DSub (female).
·
8 AES3 Out:
o
AES3 Out 1-4 - wired to 4 x XLR (male).
o
AES3 Out 5-8 - wired to 1 x DSub (male).
Note that
AES IN 5-8
and
AES OUT 5-8
connect to the RTW meter, if either of the TM 7 or TM 9
options are fitted.
·
8 GPIO
- wired to 2 x DSub.
·
2 Stereo Headphones
- wired to the headphone 1 & 2 connectors on the console's front buffer.
·
1 MADI or 1 RAVENNA
- the local I/O board is available in two versions, connecting to the Nova73 via
either MADI or RAVENNA (see
). You will need to reserve one MADI, or one
RAVENNA, port within the Nova73 for this connection.
Please see
for more details on wiring, pin-outs and jumper switch options.
Summary of Contents for mc256 MKII
Page 1: ...Technical Manual mc 56 MKII Version 5 10 2 1 Edition 12 September 2017...
Page 350: ...mc 56 MKII Technical Manual V5 10 2 1 350 Chapter 7 Appendices Local I O Wiring...
Page 351: ...mc 56 MKII Technical Manual V5 10 2 1 351 Chapter 7 Appendices Local I O Wiring...
Page 352: ...mc 56 MKII Technical Manual V5 10 2 1 352 Chapter 7 Appendices Local I O Wiring...