9. OPERATING CHECKS
9.1 MALFUNCTIONS
SELF-DIAGNOS-
TIC
The display located on the control panel (Photo N
- 7) also has the function of showing any active
alarms on the machine concerning to the control
board operation; in case of alarm will be shown the
code and a brief description of the error.
Here below is the list of error messages with the
corresponding diagnostic:
Alarm #id
Meaning
Solution
AL_1: Function
Brushes Ammeter
Amperometric Protec-
tion Brushes motor
Check usage mode of the brushes function.
Detected elevated work current by the brushes
motor.
AL_2: Function Va-
cuum Ammeter
Amperometric Protec-
tion suction motor
Check vacuum motor absorption. Detected
elevated work current by the suction motor.
AL_3: Function Po-
werstage Fail
Power section dama-
ged
Power section of brush or vacuum motor da-
maged; replace the card.
AL_4: Function Over-
current
Overcurrent on brush
or vacuum motor ou-
tputs
Short circuit detected on the output of brushes
or vacuum motor: check connections and en-
gines status.
AL_5: Function Over-
temperature
Thermal protection on
brush / vacuum motor
section
Overheating on brushes and vacuum motor
power section: check absorptions.
AL_13: Traction Pedal
failure
Pedal connections
Check connections and pedal potentiometer
status.
AL_14: Traction Rele-
ase Pedal
Pedal pushed when
switching on machine
Detected traction microswitch closed when
switching on: release the pedal.
AL_15: Traction
Overtemperature
Thermal protection on
tracion motor section
Overheating on traction motor power section:
check absorptions.
AL_16: Traction Po-
werstage Fail
Traction power sec-
tion damaged
Traction power section damaged: replace the
card.
AL_17: Traction Over-
current
Overcurrent on trac-
tion output
Short circuit detected traction motor output:
Check connections and motor conditions.
AL_18: Traction Tract.
Ammeter
Amperometric protec-
tion traction motor
Check usage mode of the traction function.
High working current has been detected by
the traction motor.
AL_20: General EE-
prom Fail
Error reading internal
memory
Replace the card
AL_21: General Key-
off failure
Incorrect key se-
quence.
Detected rebound on the key signal: check
connections and key contact conditions.
AL_22: General Main
rele fail
General relay dama-
ged
The general relay on the board is damaged;
replace the card.
AL_23: General Over-
voltage
Overcurrent
Overvoltage detected on function board.
Check battery connections.
AL_24: Traction Batt
connection
Battery not connected
to the function board
Check usage mode of the traction function.
High working current has been detected by
the traction motor.
AL_25: General
Keyboard fail
Lack of communica-
tion dashboard-board
Check connections between the function board
and dashboard.
Summary of Contents for COMFORT XXS
Page 3: ...3 1 2 A B 1 5 4 2 7 4 5 6 9 8 3 3...
Page 4: ...4 C 1 1 D 2 3...
Page 5: ...5 3 3 2 1 4 6 7 6 7 1 2 5 E F 1...
Page 6: ...6 H 2 G 1 3 3 1 4 2...
Page 8: ...8 1 L 2 2 4 1 M 3...
Page 9: ...9 N 1 2 3 6 7 5 4...
Page 111: ......
Page 115: ......
Page 116: ...LAVORWASH S p a Via J F Kennedy 12 46020 Pegognaga MN ITALIA cod 7 504 0228 rev 01 12 2013...