Superabrasive
Owner’s Manual – Lavina
®
32R-S-E
11/2014
24
FAULT LIST LAVINA
®
32R-S-E
Fault
Additional conditions
Cause
Action
The display does not
work
Push emergency stop button
Panel turned off
Release the emergency stop
button clockwise
The panel is not connected to
the machine with a cable
No battery . Batteries
are not put correctly.
Put charged batteries in the
panel or connect it with a
cable
The display of the
panel lights and then
turns off
Discharged batteries indicator is
on
Discharged batteries
Put charged batteries in the
panel or connect it with a
cable
No connection with
the machine.
Connection indicator
shows no connection
Switch „Battery/Network“ is in
condition “Battery” .
The „Ready“ light is off.
Lack of battery,
damaged battery or
discharged battery.
Switch „Battery/Network“ to
„Network“.
Check connection and
battery condition.
Switch „Battery/Network“ is in
“Network” position.
The „Ready“ light is off.
The “Power” light is off.
No power supply in the
network.
Unplugged or damaged
feeding cable.
Check for power supply.
Check and if necessary
change the cable.
The machine does
not fulfill commands
Light „Ready“ flashes. Indication
„Emergency Stop”
Emergency stop is
pushed.
Release the emergency stop.
Light „Ready“ flashes. Indication
„Inverter Fault”
Protection on into
inverter I1,I2 or I3
Slow down the rev . Switch
„Reset Inverter”
The main motor
does not start.
Switch „Battery/Network“ is in
“Battery” position.
The „Ready“ light is on.
The “Power” light is off.
The machine is not
power supplied.
Switch „Battery/Network“ in
position „Network“.
Plug the feeding cable in the
circuit.
Upon command
„forward“
или
„backward“ the
machine turns one
side.
After a while the machine stops
and an indication shows
„Inverter Fault”
Overloaded inerter for
movement .
Switch „Reset Inverter”
No water feed.
Main motor is not on.
Condition
for
water
supply
Turn on the main motor