MAINTENANCE AND CLEANING
Remove the cup rest compartment and the spent
capsule drawer from the drop drawer.
Empty the drop drawer and the spent capsule
drawer and wash them with a mild detergent
solution.
Switch the machine off and disconnect the power
cord.
Unlock the side lock and open the door.
Clean the drop drawer housing inside the ma-
chine and the nozzle supporting spout.
The residual coffee capsules shall be disposed of
in observance of the sanitary obligations in force
in the country .
DISPENSING SYSTEM
Turn the fixing levers of mixing bowls clockwise, re-
move the product nozzles from the holder by releas-
ing them.
Disassemble all components of the dispensing system:
• extraction drawer
• water dispensing ring
• mixing bowl
• mixer
• dispensing tubes
• product dispensing nozzle holder