LAVAZZA Magystra LB 2600 INT Installation And Maintenance Manual Download Page 26

26

EN

PROGRAMMING

 

PRODUCT DECOUNTER

  Each product motor can be assigned a time credit 

in seconds that will be decreased at each dispens-

ing cycle of that product. After having used up the 

credit, the machine will answer <<selection not avail-

able>> whenever a request is made for that product. 

This control is disabled at the beginning and the 

machine has got no constraint.

  To programme the credit time of a product motor, 

set the variable by pressing key “3” and “7”.

  After having reached the time quantity you wish, 

press key “PROG”; the value will be copied be-

tween parentheses on the left of the display.

  Quit the programming mode as usual.

 That the first warning threshold can be pro-

grammed. If exceeded, the display will show an 

alarm message without interfering with the opera-

tion of the machine.

 After having used up the time credit, the operator 

may decide whether to inhibit or not the dispensing 

cycle of the selections, including that product.

       PRODUCT QTY.  

N

       [N= 0.0] 

        

0.0

       PROD. 1 WARNING  

N

       THRESHOLD 

            0

       PRODUCT STOP  

N

       ENABLE 1 =  STOP 0   

     

 

PROGRAMMING MAINTENANCE

  In this ensemble of parameters, key “2”, you can set 

up some counters to trigger an alarm after a pro-

grammable number of events (press “3” and “7” to 

set up and PROG to store).

  It sets the threshold of capsules dispensed before 

displaying the message “empty the capsule drawer”.

  The value between square brackets shows the de-

counter that will display the message once reached 

“00”. When only 5 capsules are required to reach 

the set-up threshold, the vending machine will show 

the message “empty the capsule drawer.

 Once reached the set-up threshold, the opera-

tion of the machine will be inhibited until the 

capsule drawer is emptied .

  Dispensing cycles before having to replace the 

cartridge of the external filter, if any. As soon as 

500 dispensing cycles are left, the display will show 

“change water filter” and as soon as the decounter 

has reached 0, it will display “out of service water 

filter”, thus inhibiting the operation of the machine.

  It sets the minimum time necessary (in seconds) to 

empty the capsule drawer and the drip tray; below 

the set-up value, the vending machine will not reset 

the full drawer message.

       CAPSULE DECOUNT.  

       [ 00]        

 

00

EMPTY CAPSULE

DRAWER

       H2O FILTER DECOUN.

      [000]          

0.0

       MINIM. TIME RESET  

       DRAWER CAPS 

0.0

RESET DRAWER

CAPSULE COUNTER

Summary of Contents for Magystra LB 2600 INT

Page 1: ...INSTALLATION AND MAINTENANCE MANUAL READ THE INSTRUCTIONS CAREFULLY lavazza com THEEXPERTISEOFCOFFEESHOP THEPLEASUREOFCHOICE Magystra LB 2600 INT LB 2600 MENA LB 2600 AUS...

Page 2: ......

Page 3: ...lose to flames Use the machine at room temperature Power Supply Only connect the coffee machine to a suitable socket The voltage must correspond to that indicated on the machine s label Power Cord Do...

Page 4: ...ers e g plastic cups pottery cups jugs The dispensers of drinks in open canisters may be only used for selling and dispensing drinks obtained by brewing of products such as coffee and tea reconstituti...

Page 5: ...K 12 DOOR SWITCH 12 FLAP FOR CAPSULES 12 DISPENSER 12 WATER FLAP 12 WATER TANK 12 CAPSULE GROUP 12 MIXING BOWLS 13 NOZZLES HOLDER 13 POWDER ASPIRATOR 13 AIR ASPIRATOR 13 FUSES 13 MIXER MOTORS 14 VOLUM...

Page 6: ...CT 27 TIMES 27 PROGRAMME DELAYS 27 PARAMETERS 29 LM SELECTION 30 MAINTENANCE AND CLEANING 32 CLEANING OF DRIP TRAY USED CAPSULES DRAWER 32 DISPENSING SYSTEM 33 PRODUCT CANISTERS 34 CAPSULE GROUP 36 AC...

Page 7: ...arket Water tank cover lock Drip tray Supply spout Display Power supply cable Folding rest grid Capsule insertion compartment lid General switch Beverage selection keys Water tank cover Door Amount pr...

Page 8: ...ater presence capsule presence brew unit position liquid waste empty operation temperature reached count of the number of used capsules SAFETY Energy main switch 230 V ac door switch 230 V ac two fuse...

Page 9: ...a temperature ranging from 5 C to 35 C It can not be installed in a room where water jets are used for cleaning e g large kitchens etc The machine can be installed near a wall but in such a way that...

Page 10: ...of doubt to require pro fessionally qualified personnel to check the instal lation carefully It is recommended to install a differential current de vice operating below 30 mA detaching the machine fr...

Page 11: ...med on the specific risks involved CAPACITY OF CANISTERS Instant milk Kg 0 8 Instant chocolate Kg 0 8 Used capsules drawer Pz 25 Drip tray ml 300 Water tank Lt 3 6 Top cover Display board key programm...

Page 12: ...R The LB 2600 vending machine has a fixed drink dis penseronthecupsupportsurfaceandaflapsupportfor small cups The dispensing compartment in stand by is lit up by a led turning off during the dispensin...

Page 13: ...Fuses must be necessarily replaced by specialised technical personnel only MACHINE COMPONENTS Themicroswitchesinsertedintothecapsuleflapareused to detectthecapsulepassageintheunit detectthecor rect c...

Page 14: ...estab lished by the time set in the water N parameter only PRODUCT MOTORS They are intended to rotate the worm screws inside instant product canisters to pour the product quan tity necessary for sele...

Page 15: ...cekeyintothedoorswitchtopowerthesys tem The vending machine is supplied and running to all effects The mobile parts of the coffee group will be handled act extremely carefully The start up test messag...

Page 16: ...ure shall reach the pre set value Now the vending machine is ready to dispense on a free basis and the display will alternatively show some stand by messages INSTALLATION END INSTALLATION PLEASE WAIT...

Page 17: ...pensing The outlet the dimension of which can be either standard or smaller has got a closing baffle to protect the products containers are closed by a cover Power off the vending machine by means of...

Page 18: ...oor of the machine and use the service key in the safety switch The vending machine is supplied and running to all effects in this mode of operation Act extreme ly carefully PROGRAMMING Press the PROG...

Page 19: ...for one second it stops for the seconds set up here from 01 to 15 and it resumes the usual dis pensing cycle COFFEE DOSE CC 00 COFFEE SEQUENCE FIRST 1 Scrolling with 2 you can change the product pa r...

Page 20: ...sec ond milk dispensing cycle To establish the mixer rotation time of the second milk dispensing cycle If other than zero the mixer power on will be de layed by the time you have set up To determine m...

Page 21: ...ild up TIME TESTS To check the rotation time of a product motor and a mixer fan or the activation time of a solenoid valve during the programming phase when the display shows PRODUCT N or WATER N time...

Page 22: ...he pump and the brewing solenoid valve for a time set up here for three times Eachactivationwilllastonethirdoftheprogrammed value suspended by two second breaks It sets up after how many minutes after...

Page 23: ...water will be dispensed BUTTON STOP 1 ENABLED 0 PAUSE TIME AFTER DISPENSING 0 0 ASCENT TIME 0 0 PAUSE TIME AFTER THE ASCENT 0 0 FIRST INSTALLATION 0 FIRST 1 Deinstallation it s used to empty water cir...

Page 24: ...circuit of the coffee unit to check its correct operation Press key 2 to access diagnostics and to enable the machine to display keys 3 and 7 the stand by message and the water temperature in the ther...

Page 25: ...requiring the operator to wash Place a cup beneath the dispensing nozzles and press keys 5 and 8 at the same time SWITCHING ON TIME 00 00 SWITCHING OFF TIME 00 00 CLEANING TIME 00 00 CLEANING PRESS P...

Page 26: ...NTENANCE In this ensemble of parameters key 2 you can set up some counters to trigger an alarm after a pro grammable number of events press 3 and 7 to set up and PROG to store It sets the threshold of...

Page 27: ...e specified are in tenths of seconds e g 27 equals 2 seconds and 7 tenths CONFIGURATION The generic parameters intended to dispense the drinks with the different possible products are sup plied here b...

Page 28: ...28 EN PROGRAMMING...

Page 29: ...29 EN PARAMETERS Small Medium Large...

Page 30: ...sings are Dispensingcycleof1stmixedmilk atlowspeedrate 10 15 second pause dispensingcycleof2ndmixedmilk athighspeedrate 12 20 second pause dispensing cycle of espresso coffee The different milk consis...

Page 31: ...he minimum and maximum values you can assign to programmable variables As regards any parameter not contained in this document please refer to the FRESH MILK MODULE technical manual maximum credit max...

Page 32: ...r and soap be fore handling the machine and the products Only use potable water All components must only be cleaned with warm running water Components can be washed in the dishwasher at a temperature...

Page 33: ...n the drop drawer housing inside the ma chine and the nozzle supporting spout The residual coffee capsules shall be disposed of in observance of the sanitary obligations in force in the country DISPEN...

Page 34: ...NING Extract the mixer fan just by pulling it Check the wear state of the w ring sheathing the mixer motor shaft Replace if worn Wash the assembly of disassembled parts with plen ty of lukewarm water...

Page 35: ...product canister and remove the two red plugs from the outside Remove the stirring wheel Wash the disassembled parts with plenty of lukewarm water To replace the product motor follow the procedure bel...

Page 36: ...metal panel Lift slightly and extract the panel All internal components of the machine can be now accessed COOLING FAN AND POWDER ASPIRA TORS Carefully check that the rotors of the two fans on the re...

Page 37: ...ng every single component and subdi viding the parts according to the nature of materi als CLEANING INNER SIDE OF THE MACHINE Removeanytraceofresidualsfromtheinternalsurfac es of the machine specially...

Page 38: ...Water level low in the inner tank or no water OFF 7 OFF 7 A Volumetric counter Water flow counting error in hydraulic circuit The volumetric counter is blocked or can not detect pulses in water flow t...

Page 39: ...the selection keyboard and supplies the leds intended to illuminate the cup compartment the button for access to the to the programming mode of the machine is secured at the back of the display board...

Page 40: ...CV Volumetric counter MP Volumetric pump TB Termoblock GC Capsule group M1 Mixer ER Dispenser VRG Drip tray T1 Silicon hose 06 09T T2 Silicon hose 07 11T T3 Silicon hose 04 06T T4 Silicon hose 02 04T...

Page 41: ...1 2 products motor MV1 2 aspirator motor MX1 mixer motor P1 8 drinks selection buttons PB1 boiler pump PP1 3 preselection buttons Q1 boiler thermostat RB1 boiler resistance RT2 ptc device S1 water tan...

Page 42: ...42 EN ELECTRICAL PLAN CPU DISPLAY TQ TURQUOISE PK PINK WH WHITE GY GREY VT VIOLET BU BLUE GN GREEN YE YELLOW OG ORANGE RD RED BN BROWN BK BLACK...

Page 43: ......

Page 44: ...ducer Rhea Vendors Group S p A Via Valleggio 2 bis 22100 Como CO Italia machine manufacturer Rheavendors Industries S p A Via Garavaglia 58 21042 Caronno Pertusella VA Italia Model LB 2600 10086290 02...