23
EN
PROGRAMMING
Enabling this function, only during a selection deliv-
ery the selection can be interrupted by pressing any
selection key.
After dispensing, the piston will wait for the time set
up here (in seconds) before starting its stroke up.
It sets up the time (in seconds) the coffee unit pis-
ton requires to move from the dispensing position
to the decompressing position.
It sets the break time (in seconds) in the decom-
pressing position, after which it will reach the wait-
ing position. If the value of the three variables is
zero, the action is not carried out.
It is used to ensure hydraulic circuit filling at first
power-on after disinstallation. If the value is zero, at
next power-on, the machine will perform the cycle
as described in paragraph “FIRST POWER-ON”.
About 50 cc of hot water will be dispensed .
BUTTON STOP
1=ENABLED
0
PAUSE TIME AFTER
DISPENSING
0.0*
ASCENT TIME
0.0*
PAUSE TIME AFTER
THE ASCENT
0.0*
FIRST INSTALLATION
0=FIRST
1
Deinstallation it’s used to empty water circuits auto-
matically. To start the sequence, press button “3”.
About 50 cc of hot water will be dispensed .
Remove the water tank and press “1”, as it is shown
on the display. The water circuit will be totally emp-
tied during uninstallation.
Wait for the phase to come to an end when the dis-
play shows the “end of uninstallation” message.
It loads the “1A” standard configuration pre-set by
default.
DETERMINE THE SUCTION FAN TIME
To remove the residual powder of instant products
from inside the machine, it is recommended to use
the value in minutes you have already programmed
(one). If you should use particularly volatile prod-
ucts, increase the time to five (and more) minutes.
REMOVE WATER
TANK PRESS SEL. “1”
DEINSTALLATION
IN PROGRESS
END
DEINSTALLATION
DATI STD. V 1A
3=START
DEINSTALLATION
3=START