“LB 2000 OFFICE COFFEE SERVICE”
M
ANUAL CODE
83356 / R
EL
. 0.00 / M
ARCH
2005
8
4/5
Troubleshooting
Error
What has happened
Possible cause
Where to find the cause
code
Out of maximum time for
dispensing
Out of maximum time for
rest
Out of maximum time for
return
The rest microswitch was
activated while the unit
was going into working
position.
The dispenser unit has not
been positioned in the
dispenser position in the
time predetermined by the
manufacturer
The dispenser unit has not
been positioned in the rest
position in the time
predetermined by
themanufacturer
The dispenser unit has
exceeded the dispenser
position without stopping.
Gear motor power insufficient
or not appropriate
Working microswitch broken or
disconnected
Motor of gear malfunctioning
or broken
CPU card malfunctioning
Power card malfunctioning
(TRIAC)
Gears broken
Gear motor power insufficient
or not appropriate
Rest microswitch broken or
disconnected
Motor of gear motor
malfunctioning or broken
CPU card malfunctioning
Power card malfunctioning
(TRIAC)
Gears broken
Rest microswitch broken or
disconnected
Working microswitch broken or
disconnected
Inverted wiring on the motor
of the gear motor
83
(•)
84
(•)
85
86
(•)