background image

18 

INSTALLATION AND MAINTENANCE MANUAL  

554515_A_PUB_DATE_1_FEB_2014.DOC 

 

WARNING! 

ALTHOUGH THE APPLIANCE MAY BE IN THE „OFF“ POSITION, THERE IS STILL ELECTRICAL 
POWER TO THE SWITCH SUPPLY TERMINALS. 

 

WARNING! 

WHEN POWER SUPPLY HAS BEEN SWITCHED OFF WAIT FOR AT LEAST 10 MINUTES BEFORE 
STARTING INSPECTION OR SERVICING THE WASHER. BEFORE STARTING INSPECTION OF 
FREQUENCY INVERTER, CHECK FOR RESIDUAL VOLTAGE ACROSS MAIN CIRCUIT TERMINALS 
+ AND -. THIS VOLTAGE MUST BE BELOW 30 VDC BEFORE YOU CAN ACCESS THE INVERTER 
FOR INSPECTION. 

 

WARNING! 

DO NOT ALLOW CHILDREN TO PLAY ON, IN OR AROUND THE APPLIANCE AT ANY TIME. CLOSE 
SUPERVISION OF CHILDREN IS NECESSARY WHEN THE APPLIANCE IS USED NEAR CHILDREN. 
NEVER PERMIT CHILDREN TO OPERATE THE APPLIANCE. 

 

WARNING! 

DO NOT OPEN DOOR UNTIL CYLINDER REMAINS STOPPED AND WATER HAS BEEN DRAINED 
COMPLETELY. IF THE DOOR SAFETY LOCK DOES NOT WORK, DO NOT USE WASHER UNTIL 
THE DOOR LOCK MECHANISM IS REPAIRED. 

 

WARNING! 

FOLLOW ALL VALID BASIC SAFETY RULES AND LAWS. THE INSTRUCTIONS IN THIS MANUAL 
CANNOT ACCOUNT FOR EVERY POSSIBLE DANGEROUS SITUATION. THEY MUST BE GENERALLY 
UNDERSTOOD. CAUTION AND CARE ARE FACTORS WHICH CAN NOT INCLUDED IN THE DESIGN 
OF THE APPLIANCE AND ALL PERSONS WHO INSTALL, OPERATE OR MAINTAIN THE APPLIANCE 
MUST BE QUALIFIED AND FAMILIAR WITH THE OPERATING INSTRUCTIONS. IT IS UP TO THE USER 
TO TAKE PROPER CARE WHEN OPERATING THE APPLIANCE. 

 

WARNING! 

DO NOT REMOVE WARNING SIGNS PLACED ON THE APPLIANCE. OBSERVE SIGNS AND LABELS 
TO AVOID PERSONAL INJURIES. SAFETY LABELS APPEAR AT CRUCIAL LOCATIONS ON THE 
APPLIANCE. FAILURE TO MAINTAIN LEGIBLE SAFETY LABELS COULD RESULT IN INJURY TO 
THE OPERATOR OR SERVICE TECHNICIAN. 

 

WARNING! 

IF THE INSTALLED APPLIANCE OPERATE WITH COIN, TOKEN OR SIMILAR OPERATION FOR USE 
IN SELF-SERVICE SITUATIONS, THEN THE OWNER-INSTALLER MUST PROVIDE A REMOTE-
LOCATED EMERGENCY STOP DEVICE. THIS DEVICE MUST BE PLACED IN SUCH A WAY THAT IT 
IS EASY AND SAFELY ACCESSIBLE FOR THE USERS. THE EMERGENCY STOP DEVICE TAKES 
CARE THAT AT LEAST THE CONTROL CIRCUIT OF THE APPLIANCE IS INTERRUPTED. 

 

CAUTION! 

MACHINE WITH WEIGHING SYSTEM: 
NEVER CARRY LOAD SENSORS BY THEIR CABLES! 
AVOID ELECTRIC WELDING NEAR THE LOAD SENSORS! 
AN IMPACT MIGHT CAUSE PERMANENT DAMAGE TO THE LOAD SENSORS! AVOID UNEQUAL 
LOAD DISTRIBUTION BETWEEN THE LOAD SENSORS WHEN PUTTING THE MACHINE DOWN. 
WHEN THE POWER OF THE MACHINE IS SWITCHED ON, THE SYSTEM NEEDS A 10-MINUTES 
WARM-UP TIME. THIS IS IMPORTANT WHEN THE POWER HAS BEEN OFF FOR MORE THAN FIVE 
MINUTES. IGNORING WARM-UP MIGHT RESULT IN A MAJOR ERROR IN WEIGHING. 

 

!

!

!

!

!

!

!

!

Summary of Contents for LH-550

Page 1: ...High spin industrial washer extractors 33kg 40kg 55kg 80kg 100kg 120kg Original user s manual Original installation and maintenance manual 554515 A Publication date 1 Feb 2014...

Page 2: ......

Page 3: ...3 SYMBOLS ON THE MACHINE DEPENDING ON THE MACHINE MODEL 6 4 OPERATION INSTRUCTION 8 4 1 BEFORE WASHING 8 4 2 OPENING THE DOOR 8 4 3 LOADING THE MACHINE WITH LINEN 8 4 4 CLOSING THE DOOR 9 4 5 PROGRAM...

Page 4: ...hazardous liquid can cause serious scalding and burning The use of hypochlorite will cause corrosion which may cause component failure under certain circumstances The warranty of the machine cannot be...

Page 5: ...a vapour outlet to prevent pressure building in the washer extractor WARNING ORIGINAL OR IDENTICAL PARTS MUST BE USED FOR REPLACEMENT IN THIS MACHINE AFTERSERVICING REPLACE ANDSECURE ALL PANELSINTHEOR...

Page 6: ...b MACHINE Figure 3 B Hanging control 1 Button for drum rotating direction of rotating is clockwise from the frontal view 2 Button for drum rotating direction of rotating is counter clockwise from the...

Page 7: ...NCREASING THE TIME SEQUENCE CONFIRM THE SELECTION INFO overview of available wash programs and program information CANCEL THE SELECTION SERVIS servicing information MOVE UP DIRECTION OF TILTING IS FOR...

Page 8: ...eeds In order to tilt the machine backwards press and hold two buttons at the same time the button for tilting see figure 3 B pos 4 and the button 5 After a certain time delay of up to approx 10 secon...

Page 9: ...SH PROGRAMS OVERVIEW Wash program 1 Hot wash intensive 90 C Wash program 2 Warm wash intensive 60 C Wash program 3 Coloured wash intensive 40 C Wash program 4 Bright wash intensive 30 C Wash program 5...

Page 10: ...ergent can lead to poor wash results and suds overflow which can damage the machine Take care that the lid of the soap dispenser is closed when the machine starts 4 8 START THE WASHER After selecting...

Page 11: ...be interrupted if you release the pressed buttons When the extreme position is reached tilting is stopped Tilting is possible only with open drum door Unloading the linen WARNING DURING UNLOADING WHI...

Page 12: ...Fill Fill failure Full stop request for Continue While filling E12 OverFill Failure due to water overfill water level above the pre set value Full stop tumble After filling or during the filling proce...

Page 13: ...nfiguration menu E80 SoapTimeOut Incorrect signal for liquid detergent dispensing Full stop tumble Whole cycle E81 No Reheat Heating Failure Full stop tumble Wash Step Traceability only E82 No Refill...

Page 14: ...r traceability For Info only Traceability function whole cycle E551 TRACEYBILIT Y Full Internal Traceability memory is full For Info only Traceability function whole cycle E560 E563 USB Errors Errorsi...

Page 15: ...RS 80 100 120 kg 180 230 275 lb WITHTWO WAYTILTING FORWARDANDBACKWARD 30 4 INSTALLATION 31 4 1 HANDLING TRANSPORT AND STORAGE 31 4 2 SPACE REQUIREMENTS 32 4 3 MACHINE POSITIONING 32 4 4 CONNECTIONS 43...

Page 16: ...mply minimally with class A requirements For safety reasons there must be kept the necessary precaution distances with sensitive electrical or electronic device s Do not change the parameters of the f...

Page 17: ...qualified service technician equipped with proper tools and measuring devices All component replacements should be made by a qualified service technician using only factory approved replacement parts...

Page 18: ...THE APPLIANCE AND ALL PERSONS WHO INSTALL OPERATE OR MAINTAIN THE APPLIANCE MUST BE QUALIFIED AND FAMILIAR WITH THE OPERATING INSTRUCTIONS IT IS UP TO THE USER TO TAKE PROPER CARE WHEN OPERATING THE A...

Page 19: ...ure could run down the walls and covers of the washer or cover the floor around the washer Do not install the washer above an open gutter Close any nearby gutters so that waste water steam cannot coll...

Page 20: ...1 DRUM DIMENSIONS Diameter mm inch 914 36 914 36 914 36 Depth mm inch 510 20 610 24 790 31 1 Drum volume dm gal 335 88 400 106 518 137 Door opening mm inch 540 21 3 540 21 3 540 21 3 WEIGHT Net weight...

Page 21: ...n 2 inch G1 4 Air pressure MPa bar PSI 0 3 0 5 3 5 43 73 Powder dispenser cups 5 5 5 Liquid soap signals 8 8 8 External liquid soap connections 6 6 6 Hosefor press airconnection machine with forward t...

Page 22: ...UM DIMENSIONS Diameter mm inch 1110 43 70 1200 47 24 1300 51 18 Depth mm inch 838 33 860 33 85 870 34 25 Drum volume dm gal 807 213 1003 265 1180 312 Door opening mm inch 530 20 86 650 25 59 WEIGHT Ne...

Page 23: ...tubes 1 x 1 x Hosefor press airconnection machinewithforwardtilting mm inch outside diameter 8 0 31 Air pressure machine with forward tilting Mpa bar PSI 0 35 3 5 51 GENERAL DATA Ambient temperature...

Page 24: ...panel 2 Tub ventilation 60mm 2 4 3 Lubrication points 4 Entry soap supply cable 5 Entry main power cable 6 Main switch 7 Hard cold water inlet 8 Hot water inlet 9 Soft cold water inlet 10 Hose connec...

Page 25: ...74 730 28 74 K 2 mm inch 1567 61 69 1567 61 69 1567 61 69 L mm inch 422 16 61 422 16 61 422 16 61 M mm inch 80 3 15 80 3 15 80 3 15 N mm inch 80 3 15 80 3 15 80 3 15 O mm inch 70 2 75 70 2 75 70 2 75...

Page 26: ...82 52 C WITHOUT LOAD mm inch 980 38 58 D mm inch 910 35 83 E mm inch 1260 49 61 F mm inch 1747 68 78 G mm inch 1878 73 94 H mm inch 614 24 17 662 26 06 I mm inch 1463 57 60 1643 64 68 J mm inch 228 8...

Page 27: ...stated in mm inches 1 Box of electrical components 2 Soap dispenser ventilation 3 Control panel 4 Soap dispenser 5 Electrical signals liquid soap 6 Steam inlet 7 Tub ventilation 8 Cover for pneumatic...

Page 28: ...83 3 27 N mm inch 210 8 26 210 8 26 210 8 26 O 1 mm inch 1900 74 80 1518 59 76 1548 60 94 P 1 for position 9 mm inch 1787 70 35 1405 55 31 1435 56 50 Q 1 mm inch 1983 78 07 1950 76 77 1980 77 95 R mm...

Page 29: ...h 1366 53 78 1394 54 88 1392 54 80 E BOTTOMOFTHEDOOROPENING mm inch 1008 39 68 1045 41 14 995 39 17 F mm inch 910 35 83 977 38 46 915 36 02 G mm inch 1993 78 46 2057 80 98 2145 84 45 H mm inch 688 27...

Page 30: ...BOTTOMOFTHEDOOROPENING mm inch 1008 39 68 1045 41 14 995 39 17 F mm inch 910 35 83 977 38 46 915 36 02 G mm inch 1952 76 85 2016 79 37 2096 82 52 H mm inch 630 24 80 660 25 98 660 25 98 I mm inch 496...

Page 31: ...ng the package Never push pull or press the components protruding from the contour line of machine front part filling door control elements belt cover water inlet and outlet pipes etc MAKE SURE THAT T...

Page 32: ...the discharged water quantity and the number of washing machines 4 3 MACHINE POSITIONING CARRYING CAPACITY OF THE FLOOR WARNING ALWAYS CONSULT THE STATIC REQUIREMENTS WITH A STATIC ENGINEER IN ORDER...

Page 33: ...1 Anchoring necessary in case of uneven or tilted floor in case of slippery surface and in case of floor with variable surface structure Anchoring also necessary in any other cases when there is a ris...

Page 34: ..._FEB_2014 DOC Figure 4 3 A Machines 33 40 55 kg 80 100 125 lb without weighing system and tilting system 1 Machine line of contour 2 Machine footing 3 Waste sump 4 Anchoring bolt not supplied with the...

Page 35: ...CE MANUAL 35 Figure 4 3 B Machines 80 100 120 kg 180 230 275 lb without weighing system and tilting system 1 Machine line of contour 2 Machine footing 3 Waste sump 4 Anchoring bolt not supplied with t...

Page 36: ...0 30 70 X5 mm inch 130 5 12 15 0 59 13 0 51 15 0 59 X6 mm inch 77 3 03 132 5 20 132 5 20 145 5 71 X7 mm inch 60 2 36 40 1 57 X8 mm inch 160 6 29 150 5 9 X9 mm inch 350 13 77 415 16 33 X10 mm inch 300...

Page 37: ...the floor it stands on the load sensor feet Take into consideration that the entire machine acts as a measuring gauge Therefore anything that you place onto the machine or anything that is in physica...

Page 38: ...5 kg 100 125 lb with forward tilting make sure the clearance is the same on both sides of the pins THREADED ROD M14 x 120 AND CHEMICAL FILLING ARE NOT SUPPLIED WITHTHEMACHINE ANCHORING BOLT SUPPLIED W...

Page 39: ...e view B shows the distance adjustment of the air spring plate pos 1 from the hinge for tilting system pos 10 by means of an arm pos 5 The bolt pos 6 must be in the middle of the slotted hole of the a...

Page 40: ...NOT SUPPLIED WITH THE MACHINE ON REQUEST VIEW FROM ABOVE Figure 4 3 J Machines 80 100 120 kg 180 230 275 lb with forward tilting and without weighing system drilling points for anchoring bolts dimensi...

Page 41: ...plate side figure 4 3 L pos 1 and the machine frame pos 2 to 133 mm 5 24 see the detailed view F 3 Set the X distance see detailed view A i e the distance between the axis of the air springs on the p...

Page 42: ...52 D 316 12 44 355 13 98 374 14 72 table 4 3 E Machines 80 100 120 kg 180 230 275 lb dimensions are stated in mm inches Figure 4 3 M Machines 80 100 120 kg 180 230 275 lb with two way tilting forward...

Page 43: ...ORTANT TEMPERATURE IN WASHING TUB The electronic controller uses the temperature sensor in the tub to control the temperature of the washing bath There are a lot of things that have influence on the t...

Page 44: ...rature direct injury will appear VENTING WARNING VAPOURS ESCAPE FROM THE MACHINE THROUGH THE AIR VENT OPENING figure 3 3 pos 2 and 15 figure 3 5 pos 2 and 7 DO NOT COVER The vent air opening is part o...

Page 45: ...D In some countries an RCD is known as an earth leakage trip or Ground Fault Circuit Interrupter GFCI or an Appliance Leakage Current Interrupter ALCI or earth ground leakage current breaker Specifica...

Page 46: ...sconnected the last one With stranded conductors use wire end tubes with an insulated sleeve 6 for L1 U L2 V L3 W N conductors Make sure there can not be accidental contact since the supply cable stay...

Page 47: ...30 6 AWG 9 6 AWG 9 63 50 50 10 AWG 7 10 AWG 7 80 63 16 AWG 5 16 AWG 5 100 80 25 AWG 3 16 AWG 5 125 100 35 AWG 2 25 AWG 3 160 125 50 35 AWG 2 200 160 70 50 250 200 95 70 300 250 120 95 Table 4 4 Manuf...

Page 48: ...usly make sure to make equipotential bonding between all these appliances The external protective terminal for this purpose is located on the rear panel of the machine frame figure 4 4 E pos 3 The min...

Page 49: ...sent figure 4 4 F to connect the liquid soap hoses Depending of the number of liquid soap pumps that will be used drill holes max 5 of 8 mm 0 315 in the plastic hose connection part for each pump On t...

Page 50: ...electric scheme of the machine Signals for supply pumps control are 24V AC Maximum current for control circuits of pumps must be limited to 10mA Lead the cable for connection of pumps control signals...

Page 51: ...emove the three striking color transport braces securing the vibrating machine components during the transport One brace figure 4 5 A pos 1 is located in the front part of the machine accessible after...

Page 52: ...into operation remove the six striking color transport braces securing the vibrating machine components during the transport The three braces are placed on the left side of the machine and three brace...

Page 53: ...reful reading of the operation manual before the machine start and following the instructions stated 6 Check of the drum rotation direction during extracting MACHINES 33 40 55 kg 80 100 125 lb LOOKING...

Page 54: ...ean the machine cabinet to remove any traces of washing soaps 4 Soap hoppers must be cleaned at the end of each working day 5 Clean up the door gaskets to remove sediments and dirt Do not use solvents...

Page 55: ...d this entire assembly is bolted to the bottom of the switchboard 4 The switch controlling element is inserted into the rubber bushing 3 located into the limiter 2 which is bolted to the drum front fa...

Page 56: ...36 between the limiters 2 and the vibration switch 4 see the side view 3 Moving the holder 6 with the switch left or right direction B you will centre the switch control element to the distance axis...

Page 57: ...nt face of the drum 2 Limiter 3 Bushing 4 Switchboard bottom 5 Vibration switch 6 Adjusting nut 7 Vibration switch holder FRONT SIDE RIGHT SIDE Figure 5 6 B Machines 80 100 120 kg 180 230 275 lb dimen...

Page 58: ...en the loosened bolts using the torque value stated in the following tables MACHINES 33 40 55 kg 80 100 125 lb TIGHTENING MOMENTS VALUES OF BOLTS AND NUTS FOR MACHINES 33 40 55 kg 80 100 125 lb figure...

Page 59: ...369 100 kg 230 lb 12 A 120 kg 275 lb M20x70 16 600 443 80 kg 180 lb 4 B 100 120 kg 230 275 lb M10x60 6 60 44 C 80 100 120 kg 180 230 275 lb M16x75 12 500 369 80 100kg 180 230lb M8x25 D 120 kg 275 lb...

Page 60: ...ATION POINTS QUANTITY AND LUBRICATION PERIODS MACHINES 33 40 55 kg 80 100 125 lb LUBRICANT Use a multipurpose lithium lubricant containing high pressure additives of consistency NLGI 2 SKF LGEP 2 ESSO...

Page 61: ...nder stress and their life service has been shortened If the belts are too loose they can be slipping on the pulley and cause a noisy operation In the case of need tighten the belts Change the belts i...

Page 62: ...faces If all points A B C D are touching the ruler the pulleys are aligned 1 Main housing with the pulley 2 Drum 3 Drive motor 4 Ruler Figure 5 9 5 10 WATER AND STEAM FILTERS Machines are equipped wit...

Page 63: ...the casing 2 from the door bearer 3 always by a whole turn that the groove in the casing thread 2 appears bellow the securing bolt 1 3 To make the casing turning 2 easier use the semicircle notches 4...

Page 64: ...not been sufficient exchange the door seal 5 12 SPRING UNIT MACHINES 33 40 55 kg 80 100 125 lb Spring units figures 5 12 A pos 1 are to be adjusted in the case that you found out the suspended machine...

Page 65: ...O case a higher value If the fuse blows again do not change it but find the cause of the failure Contact your commercial distributor for help if necessary 5 14 EARTH LEAKAGE TRIPS If the laundry is eq...

Page 66: ...RE DURING OPERATION When the power supply has been interrupted during a washing cycle the door lock stays in a blocked position and the door cannot be opened UNBLOCKING OF THE DOOR LOCK IN CASE OF EME...

Page 67: ...NCE MANUAL 67 Figure 6 1 A Machines 33 40 55 kg 80 100 125 lb view from above Figure 6 1 B Machines 80 100 120 kg 180 230 275 lb door lock cover 6 2 ERROR INDICATION SHOWN ON DISPLAY See User s manual...

Page 68: ...e parts drain valve 1 way inlet valve 2 way inlet valve 3 way inlet valve steam valve door lock microswitch door lock coil fuses thermostat sensor motor contactor heating contactor heating element V b...

Page 69: ...y For the production of the machine that you have purchased natural resources are being reclaimed and used The machine can contain substances which are dangerous for health and environment When you di...

Page 70: ...INSTALLATION CARRIED OUT BY SERIAL NUMBER ELECTRICAL DETAILS VOLT PHASE HZ NOTE ANY CONTACTS WITH YOUR DEALER REGARDING MACHINE SAFETY OR SPARE PARTS MUST INCLUDE THE ABOVE IDENTIFICATION MAKE CERTAI...