- 34 -
PRINT AT CYCLE END
(default
): function enabling to print batching data at cycle end.
-
: print enabled
-
: print disabled
NUMBER OF BATCHING PRINTOUTS
(from 1 to 9; default: 1): number of copies of the batching printout.
CHECKING PC PRESENCE
(default:
): check for a PC connected to the instrument.
-
: PC presence check active; the instrument checks for a PC every 10 seconds. If no PC
presence is detected, the instrument will display an alarm signal
alternated with the weight
value.
-
: PC presence check not active.
WARNING:
The check is active only if selected the Modbus protocol.
WAITING CONFIRMATION FROM PC (SLAVE)
(default:
): waiting for confirmation of record batching data from PC.
-
: check enabled; the instrument waits for the PC to read the batching data, before starting
another batching. In case of recording failure, the instrument displays an alarm
.
-
: check disabled; at cycle end, the instrument will not wait for data recording on PC before
performing another batching.
SWITCHING OF THE ALARM RELAY ON WEIGHT
(from 0 to max full scale; default: 0): by setting a value different from zero, the ALARM
contact does not switch over in case of alarm, but behaves as a SETPOINT contact; the relay closes
when the weight reaches the value set in this parameter.
SWITCHING OF THE TOLERANCE RELAY ON WEIGHT
(from 0 to max full scale; default: 0): by setting a value different from zero, the
TOLERANCE contact does not switch on the basis of tolerance, but behaves as a SETPOINT
contact; the relay closes when the weight reaches the value set in this parameter.