10
10. TECHNICAL DATA
Cordless Mixer Tool Weight
8 lbs. (3.63 kg)
Cordless Mixer Dimensions
17" x 3.5" x 12.5" (43 x 9 x 31.75 cm)
Battery Information
20 Lithium Ion
Charger Information
~30 minutes
11. TROUBLE SHOOTING
Please review the attached trouble shooting guide. For any other questions or assistance, please contact LATICRETE
®
Technical Services at 800.243.4788, ext. 1235.
PROBLEM OBSERVED
POSSIBLE CAUSES
RECOMMENDED SOLUTIONS
Trigger depressed, motor does not start
n
Battery drained or low
n
Speed control knob turned down
n
Battery not fully inserted
n
Cartridge fully dispensed, mixer shuts
n
Recharge battery
n
Increase speed setting
n
Remove and reinstall battery
n
Remove used cartridge off automatically and replace with new
Trigger depressed, motor running but
material is not being dispensed
n
Clutch is disengaged
n
Cartridge tip not removed
n
LATAPOXY
®
310 Stone Adhesive too cold
n
Adhesive has cured in mixing nozzle
n
Cartridge failure (blow by)
n
Close clutch lever
n
Remove tip
n
Condition material to at least 65°F (18°C)
n
Change Mixing Nozzle
n
Remove cartridge. Clean pistons and teeth. Install new cartridge
Material dispensing slowly
n
Battery too low
n
Speed setting low
n
LATAPOXY 310 Stone Adhesive too cold
n
LATAPOXY 310 material partially cured in nozzle
n
Cartridge failure (blow by)
n
Recharge battery
n
Increase setting
n
Condition material to at least 65°F (18°C)
n
Replace mixing nozzle
n
Remove cartridge. Clean pistons and teeth. Install new cartridge
Dispensed LATAPOXY 310 Stone Adhesive
is not uniformly mixed
n
Material too cold
n
Material curing in nozzle
n
Cartridge failure (blow by)
n
Condition material to at least 65°F (18°C)
n
Change mixing nozzle
n
Remove cartridge. Clean pistons and teeth. Install new cartridge
Rack handle difficult to
n
Clutch closed, engaged
n
Open clutch, pull rack back
Summary of Contents for LATAPOXY 310