USER PARAMETERS
USER ACTIVE SET T GROUP °C SET T GROUP °F SET T BOILER °C
SET T BOILER °F
IMP DOSE 1
DOSE 1 sec
IMP DOSE 2
DOSE 2 sec
PREINF
PREINF sec
SET T MAT °C SET T MAT °F HOT WATER AUTO
HOT WATER sec
5
1
0
4
1
0
6
0
0
3
0
0
1
5
2
0
9
8
4
2
0
2
1
1
0
2
4
9
1
1
94
201
120
248
90
25
100
30
1
3
60
140
1
10
5
1
0
4
1
0
6
0
0
3
0
0
1
5
2
0
9
8
4
2
0
2
1
1
0
2
4
9
0
5
1
0
4
1
0
6
0
0
3
0
0
1
5
2
0
9
8
4
2
0
2
1
1
0
2
4
9
0
DATE&TIME
YEAR
MONTH
DAY
HOUR
MIN
13
2
5
17
33
GENERAL PARAMETERS
SERVICE
SERVICE SET
FILTER
FILTER SET Lt
FILTER SET US Gal CONTRAST
TIME CHANGE TIME ZONE US FULL POWER AUTO SHUTDOWN SHUTDOWN TIME EGS
GRIND CHECK GRIND CHECK sec CALIB T BOILER °C x10 CALIB T BOILER °F x10 OFFSET T GROUP °C OFFSET T GROUP °F PID PAR P
PID PAR I
PID PAR D
TIMER ON
0
0
0
0
0
1
0
0
1
0
0
3
0
0
0
0
0
0
0
1
0
2
0
1
0
PROPORTIONAL INTEGRAL DERIVATIVE
0=o
ff
1=on
co
ff
ee group
temperature
(°C).
c
off
ee group
temperature
(°F).
boiler
temperature
(°C).
boiler
temperature
(°F).
number of
pulses 1st
dose
number of
pulses 2nd
dose
0=o
ff
1=on
FUNCTION NOT
AVAILABEL ON
THE DREAM T
ti
me of
preinfusion
MAT
temperatu
re (°C).
MAT
temperature
(°F).
1= auto
mati
c
0= manual
hot water
ti
me
delivering
ex
tracti
on
ti
me with
damaged
flo
wmeter
(1st dose)
ex
tracti
on
ti
me with
damaged
flo
wmeter
(2nd dose)
0= on
1 = off
0 = on
1 = off
0 =
off
1 = on
0 =
EUROPEAN
1= FULL
POWER
0 = OFF
1 = ON
0 = OFF
1 = ON
0 = OFF
1= ON
0 = 500
1 = 1000
number of US
Gallons
0 = 30 m
1 = 45 m
0 = 5 s
1 = 10 s
0= OFF
number of
liters
PROPORTIONAL INTEGRAL DERIVATIVE
TIMER
MON
MON
TUE
TUE
WED
WED
THU
THU
FRI
FRI
SAT
SAT
SUN
SUN
on
off
on
off
on
off
on
off
on
off
on
off
on
off
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
1st
time
slot
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
2nd
time
slot
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
0.00
3rd
time
slot
ALARM HISTORY
1 02/05/13 17:24 BOILER TEMPERATURE PROBE FAILURE
2 02/05/13 17:27 COFFEE GROUP TEMPER PROBE FAILURE
FIRMWARE RELEASE 1.14
SERIAL NUMBER 000001
0= on
1 =
off
0 = on
1 =
off
0 =
off
1 = on
0 =
EUROPEAN
1 =
AMERICAN
1= FULL
POWER
0 =
ECONOMY
0 = OFF
1 = ON
0 = OFF
1 = ON
0 = OFF
1= ON
0 = 500
1 = 1000
2 = 2000
3 = 5000
number of US
Gallons
0 = 30 m
1 = 45 m
2 = 60 m
3 = 90 m
0 = 5 s
1 = 10 s
2 = 15 s
0= OFF
1=ON
number of
liters
Fig. 88