background image

Manual / Bedienungsanleitung: ES-400 RGY, ES-300 RGBV 

Version / Stand: January 11 

Page / Seite 4 of / von 8

mode: 0-69 Laser off; 70-139 sound mode; 140-209 automatic mode, 
210-255 DMX mode 

patterns / animations 

strobe (with increasing speed) 

Pointspeed 

horizontal movement* 

vertical movement* 

zoom / size*, 0..10 no effect, 11..92 increasing size, 93..146 automatic 
small to large, 147..200 dto large to small, 201..255 small to large to 
small… 

Colour: 0..19, 20..39, etc. single colours (3 for RGY, more for RGBV), 
above Patterns 

Reset: above 200 (shortly) 

10 

Rotation X (width), 0..150 static rotation, 151..255 automatic rot. 

11 

Rotation Y (height), analogue to ch 9 

12 

Rotation Z, 0..180 static rotation, 181..217 automatic rotation clockwise, 
218..255 automatic rotation counterclockwise 

*: not for all patterns. 

Maintenance / cleaning 

Always disconnect from the mains when the device is not in use or before cleaning it. 
Open the device by removing the 4 screws of the top cover (2 upper screws at back/frontpanel). Remove 
any deposits of dust, especially at the fan. Check for condensed fog fluid inside, if so, clean and rearrange 
the position of laser and or hazer. 

Mirrors need cleaning, when a “halo” is noticeable around the beam, or 

an unusual high amount of diffuse light can be seen inside the device.

Clean the mirrors with window 

cleaner and a paper towel. 

Never look directly into the light source. Always disconnect from the 

mains when the device is not in use or before cleaning it. 

Troubleshooting 

Problem

 

Possible cause 

No function / fan not working 

Check mains connection 

Effects don’t change to the beat of the music 

Adjust sensitivity with the dial on the front. 
Check if device isn’t in DMX or autom. mode 

Problems with DMX control 

Check DMX address selection 

Device not working, but fan working 

Turn device off for ca. 1 Minute. 

Technical specifications 

 

Power supply:

 AC 85-250V, 

 

Ambient temperature:

 +10°C … +35°C 

 

Power consumption:

 40 W 

 

Operation modes:

 DMX 512, automatic, music mode 

 

Lasersources:

 aircooled DPSS laser (green), laser diode (red and blue/violet) 

 

Optical power

 (at the laser)

:

 

ES-400 RGY: min. 300mW, max. 400mW, >80mW 532nm green, >220mW 655nm red 

 

ES-300 RGBV: min. 220mW, max. 300mW, >40mW 532nm green, >110mW 655nm red, >70mW 

405nm blue/violet 

 

Beam:

 ca. 3mm/1mrad 

 

Laser class:

 3b 

 

Scanning system:

 fast stepping motors 3-8kpps 

 

Weight:

 4.5 kg 

 

Dimensions: 

23 x 27 x 16 cm (W x D x  H)

 

 

Loudness:

 <70db

 

Please note 

This device has left our premises in absolutely perfect condition. In order to maintain this condition and to 
ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning 
notes written in this user manual. Laserworld cannot be made liable for damages caused by incorrect 
installations and unskilled operation! This manual is subject to change without notifice. Contact your local 
dealer for an update, or check our website 

www.laserworld.com

. Errors and omissions expected. 

For service contact your dealer, or Laserworld. Only use Laserworld spare parts. 

Summary of Contents for ES-400 RGY

Page 1: ...l 1 Safety instructions 2 Installation safety 2 INSTALLATION OPERATION 2 Using the laser 3 Control 3 DMX control 3 Maintenance cleaning 4 Troubleshooting 4 Technical specifications 4 Please note 4 Hin...

Page 2: ...install the laser in such a way that minimum distances and heights ensure the MPE is never exceeded in the public area When audience scanning is performed an operator has to be present An easily acces...

Page 3: ...reposition the laser or fogger hazer Turn the device off when not used The diode is on when the device is on Even if it is not lit If the laser is equipped with a remote connector connect an emergency...

Page 4: ...ect from the mains when the device is not in use or before cleaning it Troubleshooting Problem Possible cause No function fan not working Check mains connection Effects don t change to the beat of the...

Page 5: ...eckt sein 9 Netzstecker Kaltger tebuchse zug nglich halten 10 Ger t fest montieren um Vibrationen zu vermeiden Warnhinweise 1 Betreiben Sie das Ger t nur gem ss dieser Betriebsanleitung 2 Die L ftungs...

Page 6: ...seite k nnen Sie folgende Betriebsmodi eistellen Dip switch Modus 1 0 0 0 0 0 0 0 0 1 Automatisch 0 0 0 0 0 0 0 0 0 1 Musiksteuerung x x x x x x x x x 0 DMX Musiksteuerung Muster werde im Rhythmus ge...

Page 7: ...des Lasers berpr fen Sie dass sich das Ger t nicht im DMX oder Automatikmodus befindet Es treten Probleme bei der DMX Steuerung auf berpr fen Sie die korrekte Einstellung der Adressen Keine Funktion a...

Page 8: ...engwil Oberhofen SWITZERLAND Authorized person Supervisory board Mr Martin Werner place of business 8574 Lengwil SWITZERLAND company number CH 440 3 020 548 6 Commercial Registry Kanton Thurgau www la...

Reviews: