background image

Laserworld CS-1000RGB

Laserworld CS-1000RGB

14 / 45

15 / 45

Press „Exit“ to return to the settings menu.

Microphone Sensitivity Settings

The sensitivity of the built-in microphone for the control of the sound-to-light operation can be 

adjusted in the „SEnS“ menu. Press „Enter“ to change the settings. Use the „Up“ / „Down“ button to 

change the selection. 

The sensitivity can be adjusted between 1 and 100. Standard value is 50.

8.2.6. ILDA / COMPUTER CONTROL

The laser can be used with any laser control software that 

supports the ILDA control signal via sub-d connector. Use 

an ILDA cable to connect the Digital Analog Converter 

(DAC / ILDA interface) of the laser software to the ILDA in 

port at the laser.
The laser automatically detects if a DAC is connected and 

switches to ILDA operation. 

For safety reasons always 

make sure to first switch the laser to DMX operation 

mode

 (See 8.2.4. DMX Operation) before you connect the 

ILDA cable, to prevent unintended laser emission if the 

ILDA cable is removed by accident.

Recommended computer control software for your laser:
Showeditor

 Set with ShowNET  

www.showeditor.com

Showcontroller

 Set with ShowNET  

www.showcontroller.com

Final statement

Laserworld products are tested and product packaging is inspected before leaving our warehouse. 
Users must to follow the local safety regulations and warnings within this manual and adhereto 

any regulations within its place of use. Damages through inappropriate use will void any liability or 

warranty of our products. 
Due to continual product developments, please check for the latest update of this product manual 

at www.laserworld.com. If you do have any further questions, then please contact your dealer/place 

of purchase or use our contact section on our website. 
For service issues, please contact your dealer/place of purchase and ensure only genuine Laser-

world spare parts are used in any service repairs.
Errors and omissions excepted and products are subject to change.

Laserworld (Switzerland) AG 
Kreuzlingerstrasse 5
8574 Lengwil / SWITZERLAND 
  

Registered office:

8574 Lengwil / Switzerland 
Company number: CH-440.3.020.548-6 
Commercial Registry Kanton Thurgau
CEO: Martin Werner 
VAT no. (Switzerland): 683 180 
UID (Switzerland): CHE-113.954.889
VAT no. (Germany): DE 258030001 
WEEE-Reg.-No. (Germany): DE 90759352

www.laserworld.com
[email protected]

representative according to EMVG:
Ray Technologies GmbH
Managing Director: Martin Werner
Mühlbachweg 2
83626 Valley / Germany

Summary of Contents for CS-1000

Page 1: ...tes to read this manual fully before operating this laser Bitte lesen Sie diese Bedienungsanleitung sorgf ltig vor Inbetriebnahme dieses Showlasersystems Avant d utiliser cet appareil pour la premi re...

Page 2: ...r Information juridique L entreprise Laserworld Switzerland AG se r serve le droit d effectuer des modifications concernant leurs produits et ainsi de r pondre au d veloppement technique Ces modifi ca...

Page 3: ...tronically switched sockets Whenever possible do not use the laser projector together with large appliances especially fog machines on the same mains Ensure sufficient ventilation and do not place the...

Page 4: ...ution of radiation if cover is removed Laser radiation Avoid exposure to beam Power supply consumption Model type Wavelength Output power Production year Mains connection Operation mode settings Fuse...

Page 5: ...played back L001 L002 have no functional use please select ALL To set the sensitivity of the internal microphone refer to chapter 8 2 5 Settings 8 2 2 STAND ALONE AUTO Stand alone or Auto operation a...

Page 6: ...ress Enter and the Up Down buttons to set the desired DMX address Confirm with enter and press Exit to return to the main menu DMX Chart The laser uses 13 DMX channels so make sure that the next devic...

Page 7: ...aster Slave Press Enter to change the settings Use the Up Down button to change the selection Confirm with Enter Safety Setting The bEAu menu can switch the beam block safety on and off The beam block...

Page 8: ...ith ShowNET www showcontroller com Final statement Laserworld products are tested and product packaging is inspected before leaving our warehouse Users must to follow the local safety regulations and...

Page 9: ...gaben auf dem Ger t bzw in dieser Bedienungsanleitung Stellen Sie sicher dass das Ger t w hrend der Installation nicht mit dem Stromnetz verbunden ist Der Laser darf nur von technisch versiertem Fachp...

Page 10: ...en zum Erl schen des Gew hrleistungsanspruchs Das Ger t nicht schnell hintereinander Ein und Ausstecken schalten da dies die Lebensdauer der Laserdiode erheblich verk rzen kann Beim Transport des Lase...

Page 11: ...aktiv on wird ein stehener Laserstrahl verhindert Das Sacn Safety nur zu Testzwecken deaktivieren Das Scan Safety darf im produktiveinsatz nicht deaktiviert sein Mehr zum Safety 8 2 5 Optionen 8 2 De...

Page 12: ...Laser angeschlos sen werden sollen wird das Steuersignal ber das DMX Kabel zu den weiteren Slave Lasern durchgeschliffen B Master Laser aktivieren Der master Laser muss als Ansteuersystem festgelegt...

Page 13: ...Drehung Y automatisch 6 Verschiebung X Achse 0 127 Verschiebungsschritte X 128 255 Automatische Bewegung X 7 Verschiebung Y Achse 0 127 Verschiebungsschritte Y 128 255 Automatische Bewegung Y 8 Gr e...

Page 14: ...ojektionssitu ation des Lasercontents anzupassen Mit Enter das Men ffnen Ein Test Bild wird projiziert das die derzeitige Ausrichtung der Projek tion zeigt Durch die Up Down Steuerkn pfe k nnen die ve...

Page 15: ...geben werden Laserworld Switzerland AG Kreuzlingerstrasse 5 CH 8574 Lengwil Schweiz Sitz der Gesellschaft Lengwil Schweiz Firmennummer CH 440 3 020 548 6 Verwaltungsrat Martin Werner MWSt Nummer Schwe...

Page 16: ...is sible exposure Dans certains pays il est n cessaire de faire certifier l installation laser par un organisme de v rification agr Connectez une fiche interlock ou un interrupteur d urgence facilemen...

Page 17: ...pour une utilisation professionnelle Veuillez laisser refroidir les appareils pendant env 15 minutes chaque heure d utilisation Les ventilateurs et radiateurs aillettes etc doivent tre exemptes de pou...

Page 18: ...Enter La s lection standard est All ce qui signifie que tous les motifs sauvegard s sur la carte m re sont affich s L001 L002 n ont pas d utilisation fonctionnelle veuillez s lectionner ALL Pour r gle...

Page 19: ...p Down et confirmez avec Enter Le sous menu de r glage des adresse DMX est affich Appuyez sur Enter utilisez les boutons Up Down pour r gler l adresse DMX souhait e Confirmez avec enter et appuyez sur...

Page 20: ...Pour en savoir plus voir 8 2 3 Ma tre esclave Appuyez sur Enter pour changer les param tres Utilisez les boutons Up Down pour changer la s lection Confirmez avec Enter R glage s curit Le menu bEAu pe...

Page 21: ...m Explication finale Ce produit de m me que son emballage sont en parfait tat lors de l envoi Celui qui utilise cet appareil laser doit respecter les r glements de s curit s locales ainsi que les aver...

Page 22: ...supply Stromversorgung Alimentation 85 V 250 V AC Power consumption Stromaufnahme Consommation 60 W Operating temperature Betriebstempe ratur temp rature d op ration 10 to 35 C Dimensions Abmessungen...

Page 23: ...Laserworld CS 1000RGB Laserworld CS 1000RGB 44 45 45 45...