MeterMaster Plus
11
EN
Important notices
• The laser point indicates the measurement point of the ultrasonic
measurement area, up to which measurement takes place.
• If there are objects or obstructions in the measurement path or if
measurement takes place too close to walls, the resulting reflections
can cause false measurements. Wherever possible, verify the measured
distances along a clear line of sight.
• The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
• Fluctuations in air pressure or humidity can cause measurement
deviations, and wind noises and other sources of sound can also
falsify the results.
• Carpets, upholstery or curtains do not optimally reflect ultrasound.
Therefore in such cases please use smooth surfaces as aids, such
as shelves, mirrors etc.
• Ultrasound is not able to penetrate through glass (e.g. window panes).
• An energy-saving function switches the device off automatically.
• Clean with a soft cloth. Water may not be allowed to penetrate
the housing.
EU directives and disposal
This device complies with all necessary standards
for the free movement of goods within the EU.
This product is an electric device and must be
collected separately for disposal according to
the European Directive on waste electrical and
electronic equipment.
Further safety and supplementary notices at:
www.laserliner.com/info
Error code:
Err:
Please measure once more
Technical Data
(Subject to technical changes without notice 12.16)
Measurement range
0,6 m … 13 m
Precision
< 0,5%
Laser class
2 < 1 mW
Laser wavelength
630-660 nm
Power supply
Type 9V E block
Dimensions (W x H x D)
63 x 131 x 38 mm
Weight (incl. battery)
0,15 kg
Automatic switch-off
30 sec.
Operating temperature
0 °C … 40 °C
Summary of Contents for MeterMaster Plus