background image

 

    

 
 
 
 

COLUMN PRESS 120 ton 

WITH ELECTRIC PUMP 

 

“EE12018” 

 

 

 
 
 
 

LARZEP, S.A. 

 

 

LARZEP AUSTRALIA PTY. LTD.        

LARZEP AUSTRALIA PTY. LTD. 

Avenida Urtiaga, 6 

  

139 Wedgewood Road,  

      

49A Sustainable Avenue 

48269 MALLABIA, SPAIN 

HALLAM, VIC. 3803 AUSTRALIA       

BIBRA LAKE, WA 6163 AUSTRALIA 

Tel.  +34  943 171200    

Tel.  +61 (3) 9796 3744   

 

Tel. +61 (8) 9418 4988      

Fax. +34  943 174166   

Fax. +61 (3) 9796 5964   

 

Fax. +61 (8) 9418 2644 

e-mail: 

[email protected]

 

e-mail: 

[email protected]

    

e-mail: 

[email protected]

 

www.larzep.com

 

           

www.larzep.com.au

 

 

 

www.larzep.com.au

 

 

Summary of Contents for EE12018

Page 1: ...oad 49A Sustainable Avenue 48269 MALLABIA SPAIN HALLAM VIC 3803 AUSTRALIA BIBRA LAKE WA 6163 AUSTRALIA Tel 34 943 171200 Tel 61 3 9796 3744 Tel 61 8 9418 4988 Fax 34 943 174166 Fax 61 3 9796 5964 Fax 61 8 9418 2644 e mail sales larzep com e mail sales larzep com au e mail sales larzep com au www larzep com www larzep com au www larzep com au ...

Page 2: ...ge equipment The hydraulic equipment should not be exposed to temperatures grater than 60ºC when in use or when stored If purchasing just a cylinder or pump for use in a press ensure that you are using the proper combination of pump cylinder and press frame before assembling the unit We recommend you seek professional advice on the matter When choosing a place for the press ensure that it will be ...

Page 3: ...t will be necessary to act the start switch locate din the same electrical cabinet The stop of the cylinder is produce putting the command of the directional valve in position C The construction of machine has been calculated to bear without any breaking under conditions of foreseen utilization and for the whole life of the machine The hydraulic components have been designed and calculated in comp...

Page 4: ...ical cabinet 2 Check the rotate of the motor 3 If the rotate sense is the opposite of the labelled arrow in the motor change the phases of the electrical connection Disconnect the equipment for this operation 4 Put the distributor valve s command ion A position The cylinder s piston advances familiarize with the speed 5 Guide the piston to the end of the stroke and submit to pressure check the rea...

Page 5: ...ged 6 Repair the body of the cylinder Pneumatic problem 7 Check the installation 2 The cylinder does not reach pressures Pressure relief valve unrated 8 Rate the valve Cylinder pressure retainer damaged See Solution 4 Cylinders body damaged See Solution 6 3 The cylinder does not maintain pressure Cylinder pressure retainer damaged See Solution 4 Directional valve damaged See Solution 5 4 The cylin...

Page 6: ...6 Instruction Manual Column Press with Electric Pump EE12018 8 DECLARATION OF CONFORMITY ...

Page 7: ...7 Instruction Manual Column Press with Electric Pump EE12018 ...

Reviews: