background image

 

Larson Electronics, LLC

 

 Phone: 

877-348-9680

 

Fax: (903) 498-3364 

www.larsonelectronics.com 

9

 of 

1

0

 

CIRCUIT BREAKER REMOVAL

HAZARD OF ELECTRIC SHOCK, BURN, OR EXPLOSION

WARNING:

 

MAKE SURE POWER IS TURNED 

OFF

 BEFORE STARTING THE 

INSTALLATION OR PERFORMING ANY MAINTENANCE.

 

 

1. Apply appropriate personal protective equipment and follow safe electrical work practices.

2. This equipment must be installed and serviced only by qualified electrical personnel.

3. Turn off all power supplying this equipment before working on or inside equipment.

4. Always use a properly rated voltage sensing device to confirm power is off.

5. Replace all devices, doors and covers before turning on power to this equipment.

FAILURE TO FOLLOW THESE INSTRUCTIONS WILL RESULT IN DEATH OR SEVERE INJURY

1. Turn off all power supplying this equipment before working on or inside equipment.

2. Remove circuit breaker in reverse order of installation.

TROUBLESHOOTING

If problems occur during installation, refer to the following guide. If trouble persists, contact Larson Electronics.

Circuit breaker fails to stay closed.

Circuit breaker trips, but no short circuit
or overload is evident.

Push-to-trip button will not trip circuit breaker.

Condition

1. Undervoltage trip not energized.
2. Shunt trip energized.
3. Short circuit or overload on system.

System voltage below undervoltage trip setting.

Circuit breaker already tripped.

Possible Causes

1. Energize undervoltage trip.
2. De-energize shunt trip.
3. Check system for short circuit or overload.

Circuit breaker already tripped.

1. Move circuit breaker handle to reset then to ON
2. Press push-to-trip button.

Solution

OTHER SAFETY INSTRUCTIONS

Check area where circuit breaker is installed for any safety hazards including personnel safety and fire hazards.

Exposure to certain types of chemicals can cause deterioration of electrical connections.

MPD-XX-CB-SF-489

 Series

 

Summary of Contents for MPD CB-SF-489 Series

Page 1: ...NG CODES RISK OF FIRE OR ELECTRIC SHOCK FIXTURE INSTALLATION REQUIRES KNOWLEDGE OF FIXTURE S ELECTRICAL SYSTEMS IF NOT QUALIFIED CONTACT A QUALIFIED ELECTRICIAN BE CERTAIN ELECTRICAL POWER IS OFF BEFO...

Page 2: ...eaker Mounting Bolt Drilling Plan Plan de perforaci n de tornillo de montaje del interruptor Plan de forage des Vis de montage du Disjoncteur Fig 3 Circuit Breaker Escutcheon Dimensions Dimensiones de...

Page 3: ...ion indicates a TRIP position and is between the ON and OFF positions See Fig 4 Circuit Breaker Reset After an automatic or accessory initiated trip or a manual PUSH TO TRIP operation the circuit brea...

Page 4: ...ngth Secci n sin alslamiento Longuer de denudage Size Tama o Calibre Number per Lug Cantidad por zapata Nombre par cosse Conductor Conductor Conducteur Type Tipo Type Ampere Range Gama en A Gamme A Ca...

Page 5: ...them B 3 Arrange wire through wire opening in auxiliary cover to avoid pinching wires 4 Replace auxiliary cover C and be careful not to pinch wires when installing cover Replace all auxiliary cover s...

Page 6: ...rical personnel 3 Turn off all power supplying this equipment before working on or inside equipment 4 Always use a properly rated voltage sensing device to confirm power is off 5 Replace all devices d...

Page 7: ...ding to rated current and function as follows Rated current In A FTU TU MCS UTE100 3P 100 UTE100 2P 100 Type of trip units Tipo de unidad de disparo Type de d clencheurs FTU Fixed thermal Fixed magnet...

Page 8: ...Type of trip units Tipo de unidad de disparo Type de d clencheurs 100A 40 C 2P Im 1000A 100A 40 C 3P Im 1000A 00 1 A 40 C 3P Im 1000A FMU Adjustable thermal Fixed magnetic T rmico ajustable magn tico...

Page 9: ...nside equipment 2 Remove circuit breaker in reverse order of installation TROUBLESHOOTING If problems occur during installation refer to the following guide If trouble persists contact Larson Electron...

Page 10: ...perate if the housing is cracked or damaged All fasteners should be properly seated USE AND CARE Unauthorized modification may impair the function and or safety of this device and could affect the lif...