background image

EXP-MS-N4X-AT-HV

Larson Electronics, LLC

 Phone: (800) 369-6671

Fax: (903) 498-3364

www.larsonelectronics.com

of

 

6

Certifications - Compliance

-

Class I, Divisions 1 & 2, Groups B, C, D

-

Class I, Zones 1 & 2, Groups IIB+H2, IIA

-

Class II, Divisions 1&2, Groups E,F,G

-

Class III, Divisions 1&2

-

Ex db IIC Gb

-

Ex tb IIC Gb Db IP66

-

NEMA 3,4,4X,7 (B,C,D), 9 (E,F,G)

Malfunction

Cause

Remedy

The load will not work

- wrong light control setting selected

- load faulty

- mains switch OFF

- adjust setting

- change load

- switch ON

The load is always working

- continuous movement in the

detection zone

- check zone setting

Load works without and identifiable 

movement

- sensor is not mounted for detecting

movement reliably

- movement occurred, but not

identified by the sensor (movement

behind a wall, movement of small

object in immediate vicinity etc.)

- securely mount enclosure

- check zone setting

The load will not work despite 

movement

-rapid movements are being

suppressed to minimize

malfunctioning or the detection zone

you have set is too small

-check zone setting

THESE  INSTRUCTIONS  MAY NOT  COVER  ALL  DETAILS  OR  VARIATIONS  OF  THIS  PRODUCT  FOR  YOUR  EQUIPMENT  OR  INSTALLATION  REQUIREMENTS.  SHOULD  FURTHER 

INFORMATION NOT COVERED BY THESE INSTRUCTIONS BE REQUIRED, PLEASE CONTACT LARSON ELECTRONICS BY EMAIL AT 

[email protected]

OR BY PHONE AT 

1-800-369-6671 FOR FURTHER ASSISTANCE.

PLEASE VISIT LARSONELECTRONICS.COM FOR 

WARRANTY

AND 

RETURN

INFORMATION.

Reviews: