![background image](http://html1.mh-extra.com/html/larson-electronics/exp-ms-n4x-at-hv/exp-ms-n4x-at-hv_instruction-manual_3736809002.webp)
EXP-MS-N4X-AT-HV
Larson Electronics, LLC
Phone: (800) 369-6671
Fax: (903) 498-3364
www.larsonelectronics.com
3
of 6
MOTION SENSOR
Operating voltage
Rated load
HF system
5.8GHz±75MHz, ISM wave band
Transmitting power <0.5mW
Power consumption
≤
0.5W(standby)
Detection zone
Max.(D x H): 16m x 15m
Detection sensitivity
/
/
/ 50%
10
%
%
%
%
%
%
Hold time
5s / 45s / 5min / 15min
Daylight sensor
2Lux/10Lux/30Lux/Disable
Mounting height
15m Max.
Motion detection
0.5~3m/s
Detection angle
150°(wall installation)
360°(ceiling installation)
Operating temperature
-25
℃
~60
℃
IP rating
IP20
Setting
ON
ON
ON
ON
ON ON
ON
ON
ON
ON
ON
I
II
III
IV
1 2
10%
50
%
7
7
5%
10
0
%
I
II
III
IV
3 4
5s
45
s
5
min
15
min
I
II
1
0
lux
2
lux
30lux
III
IV
By selecting the combination on the DIP switch, sensor data can be precisely set for each specific application.
ON
ON
D
Deetteeccttiioonn aarreeaa
Detection area can be reduced by selecting the combination on the
DIP switches to fit precisely each application.
H
Hoolldd ttiim
mee
Refers to the time period the lamp remains at 100% illumination after
no motion detected.
D
Daayylliigghhtt sseennssoorr
The sensor can be set to only allow the lamp to illuminate below a
defined ambient brightness threshold.
When set to Disable mode, the daylight sensor will switch on the lamp
when motion is detected regardless of ambient light level.
30lux:twilight operation, 2lux, 10lux: darkness operation only.
Disable
O
ON
N
ON
5 6