background image

oVerVieW

Read and follow all instructions before using these vacuums.  Please read them carefully as failure to follow these 

precautions could result in injury.  When using electrical equipment, basic safety precautions should always be 

followed.

WArninG:

  The basic vacuum is designed for dry/damp pickup.  Do not attempt to 

pick-up liquids under any condition without using an automatic shut off assembly.

The following warnings should be adhered to reduce the risk of fire, electrical shock or injury:

1.

Do noT leave vacuum unatended when plugged in.  Unplug from outlet when not in use and before servicing.

2. Electric shock could occur if used on wet surfaces.  Do noT

 expose to rain; store indoors.

3. Use only as described in this manual. Use only 

Larson Electronics

’ recommended attachments and replacement

filters.

4.

Do noT use with damaged cord or plug.  If vacuum is not working because it has been dropped, damaged, left

outdoors, or submerged in water, return it to 

Larson Electronics

 for servicing.  Call 1-800-

369-6671

 for a

return authorization number. 

 Do not return contaminated vacuums.

5.

Do noT pull, carry by cord, or use cord as a handle.  Keep cord away from heated surfaces.

6.

Do noT unplug by pulling on cord.  To unplug, grasp the plug.

7.

Do noT handle plug or vacuum with wet hands.

8.

Do noT put any objects into motor openings.  Do noT use with openings blocked.

9.

Do noT vacuum anything that is burning or smoking, such as cigarettes, matches, or hot ashes.

10. For toxic dusts, do not use without paper filter bag, intermediate filter, and HEPA filter properly installed.

11.

Do noT use in areas where flammable or combustible liquids, such as gasoline, may be present.

12.

Do noT use where oxygen or anesthetic gases are used.

13.

Do noT use an extension cord unless absolutely necessary.  If an extension cord is required, the wire size

must be 14/3 or larger and should not exceed 50 feet in length.  Extension cords must be three-wire type to

insure grounding protection.

14. Replace damaged or worn parts immediately with genuine original equipment to maintain safety.

note:

 Absolute HEPA filtered vacuums meet AnSI Standard Z9.2-1979 with UL-586 tested and labeled HEPA filter.

2

Summary of Contents for EPV-PN-2G-SS

Page 1: ...LARSON ELECTRONICS LLC 9419 US HWY 175 KEMP TX 75143 Telephone 800 369 6671 Fax No 903 498 3364 http www larsonelectronics com e mail sales larsonelectronics com OPERATING MANUAL ...

Page 2: ...r servicing Call 1 800 369 6671 for a return authorization number Do not return contaminated vacuums 5 Do not pull carry by cord or use cord as a handle Keep cord away from heated surfaces 6 Do not unplug by pulling on cord To unplug grasp the plug 7 Do not handle plug or vacuum with wet hands 8 Do not put any objects into motor openings DO NOT use with openings blocked 9 Do not vacuum anything th...

Page 3: ...ing results of the actual D O P test 3 Stage HEPA Filtration System STAGE 1 Totally enclosed double ply paper filter bag with special fold over self adhesive seal patch Throwaway bags are stenciled with caution instructions for disposal purposes Paper bags produce filtration efficiency down to 5 mi crons STAGE 2 Intermediate filter made of double ply nonwoven media The filter has a sewn in elastic...

Page 4: ... position on top of tank and fold edge over outside of tank overlapping approximately one inch 5 Insert HEPA filter being careful not to move the 2 ply intermediate filter The HEPA filter s sealing gasket must sit evenly on the tank s rim so that an air tight seal will be obtained 6 Replace the motor head assembly on top of the HEPA filter seated on top of the vacuum tank and resnap clamps 7 Line ...

Page 5: ...wet pickup conversion kit an optional accessory The kit consists of a conversion adaptor and wet pickup adaptor Installation of wet conversion adaptor 1 Carefully remove the motor head HEPA filter and 2 ply intermediate filter Set aside 2 Set the wet pickup adaptor on the tank s rim Next set the conversion adaptor on top of the wet pickup adapter and snap down clamps 3 Follow HEPA filter assembly ...

Page 6: ...termediate Filter The 2 ply intermediate filter should be replaced with every fifth 5 change of the paper bag or whenever there is damage or visible collection of debris on the outside of the filter HEPA Filter Replace the HEPA filter when loss of suction continues to occur after you have checked for an obstruction in the hose or wand installed a new 2 ply disposable paper filter bag and installed...

Page 7: ...STALLATION ITEM DESCRIPTION 1 MOTOR HEAD ASSEMBLY 2 HEPA FILTER 3 INTERMEDIATE FILTER DISPOSABLE 4 OPTIONAL INTERMEDIATE DACRON FILTER WASHABLE 5 OPTIONAL AUTO SHUT OFF ASSEMBLY 6 RECOVERY BAG DISPOSABLE 7 RECOVER CAN 8 DOLLY 7 ...

Page 8: ...se or accessories indicating wear affecting the integrity of the system should be replaced before risk factors increase We are not in a position to anticipate all of the conditions and factors involved in a particular application Suitability of this hose for use in a particular application is the sole responsibility of the user It is for this reason that the installer and end user of the system sh...

Page 9: ... gallon series Poly tool for water pick up adjustable roller wheels Extenstion hose 1 1 2 10 ft w cuffs Extension hose 1 1 2 50 ft w cuffs Hose to hose coupler 1 1 2 Neoprene extension hose 1 1 2 10 ft w cuffs Hose cuff 1 1 2 11 plastic crevice tool 1 1 2 Curved steel wand 1 1 2 5 ft 14 aluminum floor brush 1 1 2 Water squeegee tool 14 1 1 2 Carpet tool 14 1 1 2 Inlet swivel connector 1 1 2 Goose ...

Reviews: