ZEUS
25
English
K
CORRECT PROCEDURE OF DECOMPRESSION
• Zero the pressure regulator knob.
•
Move the switch (
K1
) to the
OFF
(0)
position to stop the
equipment.
•
Open the circulation - safety valve (
K2
) to discharge the
residual pressure, always turning it anticlockwise.
•
Point the gun at the tank (
K3
) of the product and press the
trigger to release pressure. At the end of the operation, insert
the gun clamp (
K4
).
Clamp inserted
Clamp released
Make sure that the electrical system is earthed and
complies with regulations.
WARNING
:
If the equipment is still under pressure after performing the operations above described because of the nozzle or
the flexible hose clogged, proceed as follows:
• Loosen very slowly the gun nozzle.
• Release the clamp.
• Point the gun at the container of the product and press the trigger to release pressure.
•
Loosen very slowly the fitting of connection from the flexible hose to the gun.
• Clean or replace the flexible hose and the nozzle.
OFF
K1
K2
K4
K3