M3
M1
M2
M6
M4
M5
OFF
Clamp released
M
M
CORRECT PROCEDURE OF DECOMPRESSION
• Move the switch (
M1
) to the
OFF
(0)
position to stop the
equipment.
• Unlock the safety clamp (
M3
).
•
Reduce pressure to the minimum
(turn counterclockwise
the pressure control knob (
M2
))
.
• Point the gun (
M4
) at the receptacle (
M5
) used to collect
the product and press the trigger to release the pressure.
When completed, activate the safety catch again.
WARNING
:
If the equipment is still under pressure after perfor-
ming the operations above described because of
the nozzle or the flexible hose clogged, proceed
as follows:
• Loosen very slowly the gun nozzle.
• Release the clamp.
• Point the gun at the container of the product
and press the trigger to release pressure.
• Loosen very slowly the fitting of connection
from the flexible hose to the gun.
• Clean or replace the flexible hose and the
nozzle.
• Open the recirculating-safety valve(
M6
) to release the
remaining pressure.
Ed. 001 - 12/2015
www.larius.eu
ZEUS LINER
21
OPEN
Never spray but recirculate
into the tank