PRESSIONE
PRESSURE
MIN
MAX
MIN
MAX
PRESSIONE
PRESSURE
F19
F19
F18
F18
F18
F18
F17
lt. 50 Tank
lt. 20 Tank
Circulation
and washing
Minimum
operation
• Open the recirculating-safety valve (
F17
).
• Turn the pressure setting knob (
F18
) clockwise to the
“CIRCULATION & WASHING” position
(drop symbol)
.
• Visually check that the wash fluid starts to re-circulate
within the tank (
F19
).
• Turn the pressure adjustment handle (
F18
) clockwise to
stop the pump.
• Closed the recirculating-safety valve (
F17
).
• Turn pressure regulating knob (
F18
) clockwise a little so
that the machine idles.
Ed. 001 - 12/2015
www.larius.eu
ZEUS LINER
13
F17
F17
OPEN
It re-circulates back into
the tank without spraying
CLOSED
It sprays out of the spray
gun