12
VEGA 23:1
English
NEVER
use thread adhesive products on the fittings.
We recommend the use of the hose included in the
standard kit.
NEVER
use a damaged or repaired flexible hose.
CONNECT THE FEEDING AIR HOSE
•
Connect the adjustment group (
F7
) to the compressed air
fitting (
F8
).
Never operate the pump without the product, in order
to prevent the gaskets to be damaged.
Never spray cleaning liquids in close rooms. It is also
recommented to place yourself far from the pump in
order to avoid the contact with the cleaning liquids
vapours.
WASHING THE NEW EQUIPMENT
• Our equipment has been tested in our factory with a light mineral
oil which is being left inside the unit for protection. Before sucking
the product, it is necessary to duly wash with a thinner.
• Plunge the suction hose (
F9
) in the container of the washing
thinner.
• Plunge the recirculation hose (
F10
) in a collector (
a metal con-
tainer is recommended
).
• Open the recirculation tap (
F11
).
• Set the pump feeding pressure at about 3 bar and open the
air valve.
F10
F9
F11
• The pump will start and will discharge the oil for the recirculation
hose. Close the recirculation tap as soon as the clean thinner
begins to flow.
• Take the suction hose out of the product container.
• At this point place the gun against the collector (
F12
) and press
the trigger in order to discharge the residual oil. Release the trigger
as soon as the clean thinner begins to flow.
• Direct the gun against the thinner container and press the trigger
in order to recover the clean thinner left inside the pump.
• As soon as the pump begins to work in an accelerated way
(“
vacuum
") close the air valve.
F12
F7
F8