23
VEGA 23:1
English
TROUBLESHOOTING
•
The pump does not work
•
The operation of the pump is ac-
celerated and without pressure
•
The pump works but it does not
stop when the chamber is full (the
pumping unit slowly moves up
and/or down)
•
By pressing the gun trigger, the
pressure of the product highly
decreases
• feeding air is not sufficient.
• Product outlet line is clogged;
•
Product inlet line is clogged;
•
Pneumatic motor is blocked in the
position of cycle inversion;
•
Some components of the pneumatic
motor are damaged ;
• The product is lacking;
• The pump is sucking air;
•
The gaskets of the pumping rod are
worn;
•
The suction valve is worn or partially
clogged;
• The suction filter is clogged;
•
The suction filter is too thin;
• The gaskets of the pumping shaft are
worn;
•
The suction valve is worn or partially
clogged;
•
The feeding valve is worn or partially
clogged;
•
upper gaskets are worn;
•
Gun nozzle is too big or worn
•
Gun filter and the filter sieve for product
outlet are too thin
• Check the air supply line. Increase
the diameter of the feeding air pipe;
• Open the recirculation nozzle and
check that the pump starts. unscrew
the high pressure filter and clean and/
or replace the filter sieve. Clean and/
or replace the gun filter;
•
Clean the suction filter;
•
Decrease the feeding pressure;
•
manually service the pneumatic
motor;
•
Disassemble the motor and inspect
it;
• Add product;
• Check the flexible suction hose;
•
Replace the lower gaskets;
•
Disassemble the suction valve. Clean
and/or replace any worn component.
•
Clean and/or replace the two discs
of the suction filter;
• Remove the fine-mesh filter disc and
leave only the large-mesh filter disc.
• Replace the lower gaskets
•
Disassemble the suction valve and
clean and/or replace any worn detail
•
Disassemble the feeding valve and
clean and/or replace any worn detail
•
Tighten the gaskets ring nut
•
Replace it with a smaller one
•
Replace them with larger-mesh filters
Solution
Possible cause
Faults
Before performing any inspection or replacement of the pump components, make always
sure to close the compressed air supply and discharge the residual pressure in the circuit.
N
N